Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Feb;42(2):299-313.
doi: 10.1080/001401399185667.

Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity

Affiliations
Clinical Trial

Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity

J B Carter et al. Ergonomics. 1999 Feb.

Abstract

This study examined whether cooling a fire-fighter with a high velocity fan, during 10 min rest pauses between, and following, 10 min work periods, decreases heat stress during repetitive fire-fighting activity. Twelve professional fire-fighters (mean age 31.8 +/- 6.7 years) completed two, 40 min work/recovery trials in an environmental chamber at 40 degrees C and 70% relative humidity (RH). One trial was termed an enhanced recovery (ER) trial and the other was termed a normal recovery (NR) trial. In both conditions subjects wore full protective clothing and breathing apparatus during the work. In the ER trial a subject removed his protective coat and sat in front of a fan during each recovery period. In the NR trial a subject merely unbuckled his coat and was not cooled by a fan during either recovery period. The group mean metabolic cost (VO2), and the exercise and recovery heart rates were significantly lower (p < or = 0.05) during the ER trial than in the NR condition. Group mean rectal temperature increased by 1.5 degrees C in the NR trial but by only 0.8 degree C during the ER trial. The latter group's more effective cooling indicates the potential of fan cooling to reduce physiological strain and decrease the risk of heat exhaustion during repetitive fire-fighting activity. The results suggest that a fire-fighter's short 10 min exposure to heavy work in a hot environment of 40 degrees C and 70% RH produces minimal heat stress in a healthy fire-fighter. However, a period of fire-fighting exposure greater than 10 min without adequate rest and cooling may lead to a significant accumulation of heat stress and fatigue during further fire-fighting activity, irrespective of physical prowess.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources