Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques
- PMID: 10028131
- DOI: 10.2165/00007256-199927010-00003
Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques
Abstract
The assessment of cardiac function, particularly cardiac output (Q) during heavy exercise is essential for the evaluation of cardiovascular factors that might limit oxygen transport. A series of invasive and noninvasive techniques has been developed for the assessment and monitoring of Q during resting and submaximal exercise conditions. However, very few techniques have been found to give accurate and reliable determinations of Q during vigorous to maximum exercise. For exercise physiologists and sport cardiologists, maximal exercise data are of primary importance. The 'gold standard' measures of cardiac function are considered to be the direct Fick and dye-dilution methods. These have been widely shown to give accurate and reliable determinations of Q during resting and submaximal exercise conditions; however, their use during maximal exercise conditions is debatable due to the inherent risks involved with each and their increasing inaccuracy during the later stages of vigorous exercise. Thermodilution has also been considered to be a relatively good method for the determination of Q during rest and exercise conditions, but recent authors have questioned its use due to the nature of the measure and its inaccuracy during strenuous exercise. Various noninvasive measures of cardiac function have been developed to overcome the problems associated with the 'gold standard' measures. The first part of this article discusses conventional techniques used in exercise physiology settings. The majority of these provide accurate and reliable determinations of Q during rest and submaximal exercise. However, very few techniques are suitable for maximal exercise conditions. Perhaps only the foreign gas rebreathe using acetylene (C2H2) meets all the criteria of being noninvasive, simple to use, reliable over repeated measurements, accurate and useful during maximal exercise.
Similar articles
-
Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.Sports Med. 1999 Apr;27(4):241-60. doi: 10.2165/00007256-199927040-00004. Sports Med. 1999. PMID: 10367334 Review.
-
Noninvasive Assessment of Cardiac Output: Accuracy and Precision of the Closed-Circuit Acetylene Rebreathing Technique for Cardiac Output Measurement.J Am Heart Assoc. 2020 Sep;9(17):e015794. doi: 10.1161/JAHA.120.015794. Epub 2020 Aug 27. J Am Heart Assoc. 2020. PMID: 32851906 Free PMC article.
-
Simultaneous determination of the accuracy and precision of closed-circuit cardiac output rebreathing techniques.J Appl Physiol (1985). 2007 Sep;103(3):867-74. doi: 10.1152/japplphysiol.01106.2006. Epub 2007 Jun 7. J Appl Physiol (1985). 2007. PMID: 17556490
-
Reproducibility of the acetylene rebreathe technique for determining cardiac output.Med Sci Sports Exerc. 1998 Jun;30(6):952-7. doi: 10.1097/00005768-199806000-00027. Med Sci Sports Exerc. 1998. PMID: 9624657
-
Methods in pharmacology: measurement of cardiac output.Br J Clin Pharmacol. 2011 Mar;71(3):316-30. doi: 10.1111/j.1365-2125.2010.03798.x. Br J Clin Pharmacol. 2011. PMID: 21284692 Free PMC article. Review.
Cited by
-
Cystic Fibrosis Transmembrane Conductance Regulator Genotype, Not Circulating Catecholamines, Influences Cardiovascular Function in Patients with Cystic Fibrosis.Clin Med Insights Circ Respir Pulm Med. 2019 Mar 29;13:1179548419835788. doi: 10.1177/1179548419835788. eCollection 2019. Clin Med Insights Circ Respir Pulm Med. 2019. PMID: 30956528 Free PMC article.
-
Aerobic Intermittent Hypoxic Training Is Not Beneficial for Maximal Oxygen Uptake and Performance: A Systematic Review and Meta-Analysis.Scand J Med Sci Sports. 2025 Jun;35(6):e70088. doi: 10.1111/sms.70088. Scand J Med Sci Sports. 2025. PMID: 40548904 Free PMC article. Review.
-
Hemodynamic responses to metaboreflex activation: insights from spinal cord-injured humans.Eur J Appl Physiol. 2009 Jul;106(4):525-33. doi: 10.1007/s00421-009-1045-2. Epub 2009 Apr 2. Eur J Appl Physiol. 2009. PMID: 19340452
-
Acyl ghrelin improves cardiac function in heart failure and increases fractional shortening in cardiomyocytes without calcium mobilization.Eur Heart J. 2023 Jun 9;44(22):2009-2025. doi: 10.1093/eurheartj/ehad100. Eur Heart J. 2023. PMID: 36916707 Free PMC article. Clinical Trial.
-
Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.J Clin Monit Comput. 2012 Apr;26(2):63-8. doi: 10.1007/s10877-012-9334-4. Epub 2012 Jan 11. J Clin Monit Comput. 2012. PMID: 22234400
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical