Sensitivity, specificity, and predictive values of three Salmonella rapid detection kits using fresh and frozen poultry environmental samples versus those of standard plating
- PMID: 10049863
- PMCID: PMC91144
- DOI: 10.1128/AEM.65.3.1055-1060.1999
Sensitivity, specificity, and predictive values of three Salmonella rapid detection kits using fresh and frozen poultry environmental samples versus those of standard plating
Abstract
To reduce human exposure to Salmonella spp. in poultry products, broiler chicken flocks have been tested by culture methods. Since the standard techniques may take 3 to 5 days, rapid detection methods have been developed. In this study we tested the performance of three rapid tests originally developed for food samples by using environmental samples obtained from poultry houses. These rapid tests were Reveal, an enzyme-linked immunosorbent assay from Neogen Corp.; BIND, a bacterial ice nucleation detection method from Idetek Corp.; and a filter monitor method from Future Medical Technologies, Inc. For the standard culture, brilliant green with novabiocin and xylose-lysine-tergitol-4 agar were used for presumptive identification, and identities were confirmed by using poly-O antisera. Environmental samples were collected from farms belonging to an integrated poultry company prior to chick placement and 1 week before slaughter. Sensitivities, specificities, and predictive values with 95% confidence intervals were calculated. Statistical differences were determined by using McNemar's chi square test. The sensitivities of the different tests were not stable, varying widely between sample times, and were affected by freezing of the samples. All of the rapid tests had low sensitivities, which led to many false-negative results. All tests were able to detect Salmonella spp. at a concentration of 10 CFU/ml in at least one of four trials. The BIND and Reveal tests were simple to use with multiple samples and reduced laboratory time by up to 1 day. Based on our results, we do not recommend that any of these rapid tests, in their present state of development, be utilized with environmental samples collected with drag swabs.
References
-
- Beckers H J, Heide J V D, Fenigsen-Narucka U, Peters R. Fate of salmonellas and competing flora in meat sample enrichments in buffered peptone water and in Mueller-Kauffmann’s tetrathionate medium. J Appl Bacteriol. 1987;62:97–104. - PubMed
-
- Beumer R R, Brinkman E, Rombouts F M. Enzyme-linked immunoassays for the detection of Salmonella spp.: a comparison with other methods. Int J Food Microbiol. 1991;12:363–374. - PubMed
-
- Blackburn C d. Rapid and alternative methods for the detection of salmonellas in foods. J Appl Bacteriol. 1993;75:199–214. - PubMed
-
- Chen H, Fraser A D E, Yamazaki H. Evaluation of the toxicity of Salmonella selective media for shortening the enrichment period. Int J Food Microbiol. 1993;8:151–159. - PubMed
-
- Fleiss J. Statistical methods for rates and proportions. 2nd ed. New York, N.Y: John Wiley and Sons; 1981. pp. 4–8.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous
