. 1999 Mar 2;99(8):1011-4.
doi: 10.1161/01.cir.99.8.1011.

In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study

Affiliations

In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study

F Prati et al. Circulation. .

Abstract

Background: The aim of this study was to evaluate the relationship between residual plaque burden after coronary stent implantation and the development of late in-stent neointimal proliferation.

Methods and results: Between January 1996 and May 1997, 50 patients underwent intravascular ultrasound (IVUS) interrogation at 6+/-1.2 months after coronary stent implantation in native coronary arteries. IVUS images were acquired with a motorized pullback, and cross-sectional measurements were performed within the stents at 1-mm intervals. The following measurements were obtained: (1) lumen area (LA), (2) stent area (SA), (3) area delimited by the external elastic membrane (EEMA), (4) percent neointimal area calculated as (SA-LA/SA)x100, and (5) percent residual plaque area calculated as (EEMA-SA)/EEMAx100. Volume measurements within the stented segments were calculated by applying Simpson's rule. In the pooled data analysis of 876 cross sections, linear regression showed a significant positive correlation between percent residual plaque area and percent neointimal area (r=0.50, y= 45.03+0.29x, P<0.01). There was significant incremental increase in mean percent neointimal area for stepwise increase in percent residual plaque area. Mean percent neointimal area was 16.3+/-10.3% for lesions with a percent residual plaque area of <50% and 27.7+/-11% for lesions with a percent residual plaque area of >/=50% (P<0.001). The volumetric analysis showed that the percent residual plaque volume was significantly greater in restenotic lesions compared with nonrestenotic lesions (58.7+/-4.3% versus 51.4+/-5.7%, respectively; P<0.01).

Conclusions: Late in-stent neointimal proliferation has a direct correlation with the amount of residual plaque burden after coronary stent implantation, supporting the hypothesis that plaque removal before stent implantation may reduce restenosis.

PubMed Disclaimer