The combination of magnetic resonance angiography and computational fluid dynamics: a critical review
- PMID: 10065891
- DOI: 10.1615/critrevbiomedeng.v26.i4.10
The combination of magnetic resonance angiography and computational fluid dynamics: a critical review
Abstract
Computational Fluid Dynamics (CFD) has proven to be a valuable technique in the study of blood flow in arteries because of its capability of obtaining quantitatively velocities and wall shear stress. However, the "bottleneck" problem limiting the application of CFD is the difficulty of constructing anatomically realistic arterial geometries. In this survey, an overview is presented of the progress over the last decade in the development of magnetic resonance angiography (MRA) techniques, medical image processing and CFD, as well as the combination of these techniques in hemodynamics research. It is demonstrated that with modern angiographic techniques such as MRA, noninvasive measurement of human angiograms becomes possible and practical. Together with digital medical image processing and analysis techniques, computational models can be constructed for the "real" human arteries without making any geometric assumptions. When allied with state-of-the-art CFD codes, velocity and wall shear stress distributions, as well as particle trajectories, can be determined in the arteries.
Similar articles
-
Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics.NMR Biomed. 2009 Oct;22(8):795-808. doi: 10.1002/nbm.1389. NMR Biomed. 2009. PMID: 19412933
-
Reconstruction of blood flow patterns in human arteries.Proc Inst Mech Eng H. 1999;213(5):411-21. doi: 10.1243/0954411991535022. Proc Inst Mech Eng H. 1999. PMID: 10581968
-
Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: "A Preliminary Framework Analysis".Cardiovasc Eng Technol. 2018 Mar;9(1):1-31. doi: 10.1007/s13239-017-0332-z. Epub 2017 Nov 9. Cardiovasc Eng Technol. 2018. PMID: 29124548
-
Image-based computational fluid dynamics modeling in realistic arterial geometries.Ann Biomed Eng. 2002 Apr;30(4):483-97. doi: 10.1114/1.1467679. Ann Biomed Eng. 2002. PMID: 12086000 Review.
-
Non-contrast enhanced MR angiography: physical principles.J Magn Reson Imaging. 2012 Aug;36(2):286-304. doi: 10.1002/jmri.23641. J Magn Reson Imaging. 2012. PMID: 22807222 Review.
Cited by
-
Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics.Magn Reson Med. 2009 Feb;61(2):409-17. doi: 10.1002/mrm.21861. Magn Reson Med. 2009. PMID: 19161132 Free PMC article.
-
Comparing velocity and fluid shear stress in a stenotic phantom with steady flow: phase-contrast MRI, particle image velocimetry and computational fluid dynamics.MAGMA. 2015 Aug;28(4):385-93. doi: 10.1007/s10334-014-0476-x. Epub 2014 Dec 12. MAGMA. 2015. PMID: 25502616
-
Wall shear stress measurement using phase contrast magnetic resonance imaging with phase contrast magnetic resonance angiography in arteriovenous polytetrafluoroethylene grafts.Angiology. 2009 Aug-Sep;60(4):441-7. doi: 10.1177/0003319709335908. Epub 2009 Jul 21. Angiology. 2009. PMID: 19625275 Free PMC article.
-
Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation.Ann Biomed Eng. 2008 Nov;36(11):1793-804. doi: 10.1007/s10439-008-9561-5. Epub 2008 Sep 12. Ann Biomed Eng. 2008. PMID: 18787954 Free PMC article.
-
Pulmonary Artery Shear Stress and Oscillatory Shear Index are Associated with Right Ventricular Remodeling in Repaired Tetralogy of Fallot.Ann Biomed Eng. 2025 Sep;53(9):2206-2222. doi: 10.1007/s10439-025-03793-0. Epub 2025 Jul 3. Ann Biomed Eng. 2025. PMID: 40610780 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous