Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates
- PMID: 10069728
- DOI: 10.1097/00003072-199903000-00008
Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates
Abstract
Purpose: Quantitative results are often obtained from images after drawing regions of interest (ROIs) about the organ or area being evaluated. The accuracy and reproducibility of ROIs is an important aspect of quality-control protocols. Attempts to increase ROI accuracy and precision by generating them automatically must be compared with manually processed images to evaluate the success of the automatic methods. Operators' abilities to reproduce ROIs and the effect this has on the reproducibility of estimating glomerular filtration rate from renograms were assessed.
Methods: Estimation of the glomerular filtration rate using Sampson's method requires a) exclusion ROIs around both kidneys for background subtraction, b) whole-kidney ROIs, and c) exclusion ROIs for the collecting system. Two nuclear medicine professionals were asked to produce glomerular filtration rate estimates for 20 patients with diverse renal function. This was repeated 1 month later. The intra- and interoperator variations were calculated for the glomerular filtration rate results and on a pixel basis for the ROIs.
Results: THE percentage of common pixels, on average, for a) intraoperator repeats and b) interoperator comparisons were a) 95%, 94%, 85%, and b) 94%, 93%, and 81% for region types 1, 2, and, 3, respectively. Analysis of variance for the glomerular filtration rate estimates showed significant variations in estimates for left kidneys (P < 0.025) but none (P > 0.1) for right kidneys.
Conclusion: Spatial reproducibility in ROI drawing does not necessarily relate directly to the associated quantitative reproducibility.
Similar articles
-
Effect of region of interest selection and uptake measurement on glomerular filtration rate measured by 99mTc-DTPA scintigraphy in dogs.Vet Radiol Ultrasound. 2002 Jul-Aug;43(4):383-91. doi: 10.1111/j.1740-8261.2002.tb01022.x. Vet Radiol Ultrasound. 2002. PMID: 12175004
-
Deep regression using 99mTc-DTPA dynamic renal imaging for automatic calculation of the glomerular filtration rate.Eur Radiol. 2023 Jan;33(1):34-42. doi: 10.1007/s00330-022-08970-6. Epub 2022 Jul 7. Eur Radiol. 2023. PMID: 35796790
-
Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest.J Nucl Med. 2000 Dec;41(12):1947-54. J Nucl Med. 2000. PMID: 11138677
-
Fully automatic region of interest selection in glomerular filtration rate estimation from 99mTc-DTPA renogram.J Digit Imaging. 2011 Dec;24(6):1010-23. doi: 10.1007/s10278-011-9361-6. J Digit Imaging. 2011. PMID: 21274591 Free PMC article.
-
Functional renal imaging with nuclear medicine.Abdom Imaging. 2003 Mar-Apr;28(2):176-9. doi: 10.1007/s00261-001-0184-7. Abdom Imaging. 2003. PMID: 12592463 Review. No abstract available.
Cited by
-
Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.Nucl Med Commun. 2010 May;31(5):366-74. doi: 10.1097/MNM.0b013e3283362aa3. Nucl Med Commun. 2010. PMID: 20145580 Free PMC article.
-
Prediction of glioma-subtypes: comparison of performance on a DL classifier using bounding box areas versus annotated tumors.BMC Biomed Eng. 2022 May 19;4(1):4. doi: 10.1186/s42490-022-00061-3. BMC Biomed Eng. 2022. PMID: 35590389 Free PMC article.
-
A Feasibility Study on Deep Learning Based Brain Tumor Segmentation Using 2D Ellipse Box Areas.Sensors (Basel). 2022 Jul 15;22(14):5292. doi: 10.3390/s22145292. Sensors (Basel). 2022. PMID: 35890972 Free PMC article.
-
Evaluation of software tools for automated identification of neuroanatomical structures in quantitative β-amyloid PET imaging to diagnose Alzheimer's disease.Eur J Nucl Med Mol Imaging. 2016 Jun;43(6):1077-87. doi: 10.1007/s00259-015-3300-6. Epub 2016 Jan 7. Eur J Nucl Med Mol Imaging. 2016. PMID: 26739328
-
Semi-Automated Volumetric and Morphological Assessment of Glioblastoma Resection with Fluorescence-Guided Surgery.Mol Imaging Biol. 2016 Jun;18(3):454-62. doi: 10.1007/s11307-015-0900-2. Mol Imaging Biol. 2016. PMID: 26463215 Free PMC article. Clinical Trial.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources