Comparison of double-bag and Y-set disconnect systems in continuous ambulatory peritoneal dialysis: a randomized prospective multicenter study

Affiliations
Clinical Trial

Comparison of double-bag and Y-set disconnect systems in continuous ambulatory peritoneal dialysis: a randomized prospective multicenter study

P K Li et al. Am J Kidney Dis. 1999 Mar.

Abstract

We performed a multicenter, single-blinded, prospective randomized study on the use of a double-bag disconnect system (B) versus a Y-set disconnect system (Y). The peritonitis rate, exit site infection, clinical outcome, and patients' acceptance to the procedure were assessed. A total of 120 new end-stage renal failure patients of three regional hospitals were randomized: 60 each to the B and the Y systems. The results of 60 patients on the B system and 51 on the Y system were analyzable. They were followed up for a median of 16 months. Peritonitis rates for the B and the Y systems were 33.5 and 29.4 patient-months per episode, respectively. Exit site infection rates for the B and Y systems were 17.4 and 16.0 patient-months per episode, respectively. Four catheters were removed in each group. Patients on the B system were hospitalized for 2.1 days per patient per year related to peritonitis and exit site infection, and those on the Y system were hospitalized for 1.2 days. There was no significant difference between the B and Y systems in the incidences of peritonitis (all causes and those due to coagulase-negative staphylococci), exit site infection, and in hospitalization days. However, there was a higher percentage of gram-positive infections in the Y system (52%) than in the B system (32%) and a lower percentage of gram-negative infections in the Y system (16%) than in the B system (32%). Patients on the B system had a better acceptance of the procedure than patients on the Y system, as assessed by a six-item, 10-point questionnaire (total score, 43.1 +/- 10.2 v 37.6 +/- 9.4; P < 0.005 at 1 month; 44.6 +/- 9.1 v 39.8 +/- 8.6; P < 0.01 at 6 months). From this study, it is concluded that the B and Y systems are similar in the incidences of peritonitis and exit site infection, although the B system is better accepted by patients. This is probably the first multicenter randomized study comparing the double-bag and Y-set disconnect system using only new patients who had never used other systems of continuous ambulatory peritoneal dialysis.