Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jan;11(1):47-52.
doi: 10.1016/s0924-8579(98)00047-8.

Discrepancies between mecA PCR and conventional tests used for detection of methicillin resistant Staphylococcus aureus

Affiliations

Discrepancies between mecA PCR and conventional tests used for detection of methicillin resistant Staphylococcus aureus

G F Araj et al. Int J Antimicrob Agents. 1999 Jan.

Abstract

Conventional and molecular techniques are being used in the detection of methicillin resistance in Staphylococcus aureus but they do not always show concordant results. In this study, a mecA PCR-based amplification was compared with the 1 microg oxacillin disk diffusion test and the Epsilometer test (E-test) for detection of MICs. Among 31 isolates initially characterized as MRSA by the disk diffusion test, mecA was detected in only 13 (42%) isolates. The E-test showed a wide range of oxacillin MICs (0.5 - > 256 microg/ml) among these 31 MRSA isolates: seven isolates had an MIC of > 256 microg/ml, one had 64 microg/ml, two had 4 microg/ml, two had 3 microg/ml, one had 2.5 microg/ml, nine had 2 microg/ml, three had 1.5 microg/ml, five had 1 microg/ml and one had 0.5 microg/ml. Comparing the mecA PCR results with the E-test oxacillin MIC findings revealed that mecA was detected in seven of eight isolates (87.5%) with an MIC of > or = 64 microg/ml, in three of 14 isolates (21.4%) with an MIC of 2-4 microg/ml and in three of nine isolates (33.3%) with an MIC of < 2 microg/ml. Beta-lactamase production was positive in 28/31 isolates (90.3%). Because of this variation between tests and since several resistance mechanisms are known to mediate methicillin resistance in S. aureus, the reliable detection of MRSA cannot be solely based on detection of mecA gene in S. aureus. At this stage and until new guidelines are introduced by an official body, such as NCCLS, a combination of conventional methods alone or together with a molecular method should be used every time S. aureus is tested for detection of methicillin resistance.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources