Accuracy of T1 measurement in dynamic contrast-enhanced breast MRI using two- and three-dimensional variable flip angle fast low-angle shot
- PMID: 10077009
- DOI: 10.1002/(sici)1522-2586(199902)9:2<163::aid-jmri3>3.0.co;2-l
Accuracy of T1 measurement in dynamic contrast-enhanced breast MRI using two- and three-dimensional variable flip angle fast low-angle shot
Abstract
In vivo T1 measurements, used to monitor the uptake of contrast agent by tissues, are typically performed as a first step in implementing compartmental analysis of contrast-enhanced breast magnetic resonance imaging (MRI) data. We have extended previously described methodology for in vivo T1 measurement (using a variable flip-angle gradient-recalled echo technique) to two-dimensional (2D), fast low-angle shot (FLASH). This approach requires computational modeling of slice-selective radiofrequency (RF) excitation to correct for nonrectangular slice profiles. The accuracy with which breast tissue T1 values can be measured by this approach is examined: T1 measurements from phantom and in vivo image data acquired with 2D and 3D FLASH imaging sequences are presented. Significant sources of error due to imaging pulse sequence quality and RF transmit field nonuniformity in the breast coil device that will have detrimental consequences for compartmental analysis are identified. Rigorous quality assurance programs with calibrated phantoms are thus recommended, to verify the accuracy with which T1 measurements are obtained.
Similar articles
-
Accuracy of equilibrium magnetization mapping in sliced two-dimensional spoiled gradient-recalled echo pulse sequence with variable flip angle.J Magn Reson Imaging. 2013 Nov;38(5):1245-50. doi: 10.1002/jmri.24023. Epub 2013 Feb 6. J Magn Reson Imaging. 2013. PMID: 23390025
-
[Combination of low and high resolution T1-weighted sequences for improved evaluation of morphologic criteria in dynamic contrast enhanced MRI of the breast].Rofo. 2002 Nov;174(11):1445-9. doi: 10.1055/s-2002-35350. Rofo. 2002. PMID: 12424673 German.
-
Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast.Br J Radiol. 1996 Mar;69(819):206-14. doi: 10.1259/0007-1285-69-819-206. Br J Radiol. 1996. PMID: 8800863
-
Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI.Med Phys. 2017 Mar;44(3):873-885. doi: 10.1002/mp.12095. Med Phys. 2017. PMID: 28061002
-
Dynamic MRI of the breast.Eur J Radiol. 1998 May;27 Suppl 2:S265-71. doi: 10.1016/s0720-048x(98)00073-4. Eur J Radiol. 1998. PMID: 9652533 Review.
Cited by
-
Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck.Quant Imaging Med Surg. 2012 Dec;2(4):245-53. doi: 10.3978/j.issn.2223-4292.2012.11.04. Quant Imaging Med Surg. 2012. PMID: 23289084 Free PMC article.
-
Advanced techniques using contrast media in neuroimaging.Magn Reson Imaging Clin N Am. 2012 Nov;20(4):699-713. doi: 10.1016/j.mric.2012.07.007. Epub 2012 Sep 25. Magn Reson Imaging Clin N Am. 2012. PMID: 23088946 Free PMC article. Review.
-
Pre-treatment tumour perfusion parameters and initial RECIST response do not predict long-term survival outcomes for patients with head and neck squamous cell carcinoma treated with induction chemotherapy.PLoS One. 2018 Mar 28;13(3):e0194841. doi: 10.1371/journal.pone.0194841. eCollection 2018. PLoS One. 2018. PMID: 29590180 Free PMC article.
-
Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.Magn Reson Med. 2010 Nov;64(5):1296-303. doi: 10.1002/mrm.22544. Magn Reson Med. 2010. PMID: 20632410 Free PMC article.
-
Tracer kinetic assessment of blood-brain barrier leakage and blood volume in cerebral small vessel disease: Associations with disease burden and vascular risk factors.Neuroimage Clin. 2021;32:102883. doi: 10.1016/j.nicl.2021.102883. Epub 2021 Nov 17. Neuroimage Clin. 2021. PMID: 34911189 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical