Fluorescence monitoring of antibiotic-induced bacterial damage using flow cytometry
- PMID: 10082304
- DOI: 10.1002/(sici)1097-0320(19990301)35:3<235::aid-cyto6>3.0.co;2-0
Fluorescence monitoring of antibiotic-induced bacterial damage using flow cytometry
Abstract
Background: Conventional techniques used to assess bactericidal activities of antibodies are time-consuming; flow cytometry has been used as a rapid alternative. In this study, the membrane potential-sensitive fluorescent probes bis-(1,3-dibutylbarbituric acid) trimethine oxonol (DiBAC4(3)) and Sytox Green, the redox dye cyano-2,3-ditolyl tetrazolium chloride (CTC), and the Baclite viability test kit were used to assess the effects of ceftazidime, ampicillin, and vancomycin on clinical isolates of Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus, respectively.
Methods: Bacterial cultures were grown to early exponential phase, at which point the antibiotics were added at their breakpoint values, and incubation was allowed to continue. At timed intervals, samples were stained and flow cytometric analysis was performed on a Skatron Argus 100 arc-lamp based dual-parameter flow cytometer.
Results: All the dyes successfully identified antibiotic-induced damage in the three strains, although different fluorescence responses between the dyes were observed. DiBAC4(3) and Sytox Green overestimated numbers of nonviable bacteria relative to loss of viability as judged by plate counts. CTC, a measure of respiratory activity, revealed antibiotic-induced population heterogeneity illus trated by the development of several subpopulations. The "live" component of the viability kit identified two populations corresponding to viable and nonviable organisms, whereas the "dead" component only revealed single populations, the fluorescence intensity of which increased with antibiotic exposure.
Conclusions: Flow cytometry provides a rapid and sensitive technique for the evaluation of the antibacterial activities of antibiotics. The use of a range of fluorophores specific for different cellular characteristics may be beneficial, bearing in mind the different fluorescence responses observed among the dyes used here.
Similar articles
-
A flow cytometric study of antibiotic-induced damage and evaluation as a rapid antibiotic susceptibility test for methicillin-resistant Staphylococcus aureus.J Antimicrob Chemother. 1997 Jul;40(1):77-83. doi: 10.1093/jac/40.1.77. J Antimicrob Chemother. 1997. PMID: 9249207
-
Rapid assessment of antibiotic effects on Escherichia coli by bis-(1,3-dibutylbarbituric acid) trimethine oxonol and flow cytometry.Antimicrob Agents Chemother. 1997 Sep;41(9):2001-5. doi: 10.1128/AAC.41.9.2001. Antimicrob Agents Chemother. 1997. PMID: 9303401 Free PMC article.
-
Rapid estimation of bacterial antibiotic susceptibility with flow cytometry.J Microsc. 1994 Oct;176(Pt 1):8-16. doi: 10.1111/j.1365-2818.1994.tb03494.x. J Microsc. 1994. PMID: 7799429
-
Microplate-Based Cell Viability Assay as a Cost-Effective Alternative to Flow Cytometry for Microalgae Analysis.Environ Sci Technol. 2023 Dec 19;57(50):21200-21211. doi: 10.1021/acs.est.3c05675. Epub 2023 Dec 4. Environ Sci Technol. 2023. PMID: 38048183 Review.
-
The application of multi-parameter flow cytometry to monitor individual microbial cell physiological state.Adv Biochem Eng Biotechnol. 2004;89:197-223. doi: 10.1007/b93997. Adv Biochem Eng Biotechnol. 2004. PMID: 15217160 Review.
Cited by
-
Multiparametric flow cytometry and cell sorting for the assessment of viable, injured, and dead bifidobacterium cells during bile salt stress.Appl Environ Microbiol. 2002 Nov;68(11):5209-16. doi: 10.1128/AEM.68.11.5209-5216.2002. Appl Environ Microbiol. 2002. PMID: 12406706 Free PMC article.
-
Applications of flow cytometry to characterize bacterial physiological responses.Biomed Res Int. 2014;2014:461941. doi: 10.1155/2014/461941. Epub 2014 Sep 9. Biomed Res Int. 2014. PMID: 25276788 Free PMC article. Review.
-
Rapid cytometric antibiotic susceptibility testing utilizing adaptive multidimensional statistical metrics.Anal Chem. 2015 Feb 3;87(3):1941-9. doi: 10.1021/ac504241x. Epub 2015 Jan 13. Anal Chem. 2015. PMID: 25540985 Free PMC article.
-
Fluorescent method for monitoring cheese starter permeabilization and lysis.Appl Environ Microbiol. 2001 Sep;67(9):4264-71. doi: 10.1128/AEM.67.9.4264-4271.2001. Appl Environ Microbiol. 2001. PMID: 11526032 Free PMC article.
-
Rapid assessment of the physiological status of the polychlorinated biphenyl degrader Comamonas testosteroni TK102 by flow cytometry.Appl Environ Microbiol. 2002 Apr;68(4):2031-5. doi: 10.1128/AEM.68.4.2031-2035.2002. Appl Environ Microbiol. 2002. PMID: 11916727 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous