[Evaluation of loosening of different total hip models and neck lengths (author's transl)]
- PMID: 1008730
- DOI: 10.1007/BF00418908
[Evaluation of loosening of different total hip models and neck lengths (author's transl)]
Abstract
The percentage of aseptic loosening of different types of total hip prostheses in 771 cases has been evaluated. The time of follow-up ranged between 1/2 and 6 years. In prostheses of the Charnley-Müller type of loosening was 7.8% in the Charnley-Müller-Weller type with a 2-year shorter follow-up it was 2.4%. No loosening was found during the last 2 1/2 years when the prosthesis of Beck was used, which has an increased femoral shaft-neck angle and a longer stem. When a longer neck was used, the loosening averaged 5.6%. In cases of normal neck-length it was 3.6%. From the biomechanical standpoint it seems preferable to use prostheses with an increased shaft-neck angle. Comparing the rates of loosening as reported in the literature it appears that prostheses where the femur is displaced medially (by a small femoral head or increased shaft-neck angle) show a very low rate of loosening. Models with metal sockets (McKee-Farrar and Weber-Huggler) seem to have a higher rate of loosening than models with polyethylene sockets.
Similar articles
-
[Etiopathogenesis of loosening after total hip replacement (author's transl)].Arch Orthop Unfallchir. 1977 Jun 26;88(2):139-52. doi: 10.1007/BF00415094. Arch Orthop Unfallchir. 1977. PMID: 880089 German.
-
Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement.J Arthroplasty. 1999 Apr;14(3):326-32. doi: 10.1016/s0883-5403(99)90059-1. J Arthroplasty. 1999. PMID: 10220187
-
[Further experiences with total hip arthroplasty. Clinical and roentgenographic results after 3--6 years following implantation (author's transl)].Arch Orthop Unfallchir. 1976 Mar 26;84(2):149-68. doi: 10.1007/BF00414975. Arch Orthop Unfallchir. 1976. PMID: 1267675 German.
-
Catastrophic Femoral Neck Failure after THA with the Accolade(®) I Stem in Three Patients.Clin Orthop Relat Res. 2016 May;474(5):1333-8. doi: 10.1007/s11999-015-4438-z. Epub 2015 Jul 8. Clin Orthop Relat Res. 2016. PMID: 26152781 Free PMC article. Review.
-
Factors correlating with long term survival of McKee-Farrar total hip prostheses.Clin Orthop Relat Res. 1996 Aug;(329 Suppl):S48-59. doi: 10.1097/00003086-199608001-00005. Clin Orthop Relat Res. 1996. PMID: 8769322 Review.
Cited by
-
An analysis of 119 loosenings in total hip endoprostheses.Arch Orthop Trauma Surg (1978). 1980;96(2):83-90. doi: 10.1007/BF00433286. Arch Orthop Trauma Surg (1978). 1980. PMID: 7377936
-
Results of alloarthroplasty of the hip joint.Arch Orthop Trauma Surg (1978). 1980;96(4):247-58. doi: 10.1007/BF00432862. Arch Orthop Trauma Surg (1978). 1980. PMID: 6994678 Review.
-
Technological test-methods for hip prostheses.Arch Orthop Trauma Surg (1978). 1980;97(4):285-92. doi: 10.1007/BF00380710. Arch Orthop Trauma Surg (1978). 1980. PMID: 7458613
-
Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty.Arch Orthop Trauma Surg (1978). 1983;101(2):137-43. doi: 10.1007/BF00433274. Arch Orthop Trauma Surg (1978). 1983. PMID: 6847350 No abstract available.