Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Apr;117(4):719-27.
doi: 10.1016/S0022-5223(99)70292-8.

Positron emission tomographic imaging with fluorodeoxyglucose isefficacious in evaluating malignant pulmonary disease

Affiliations
Free article
Comparative Study

Positron emission tomographic imaging with fluorodeoxyglucose isefficacious in evaluating malignant pulmonary disease

G M Graeber et al. J Thorac Cardiovasc Surg. 1999 Apr.
Free article

Abstract

Objective: Positron emission tomography (PET), when used with the intravenously administered radiopharmaceutical F-18 fluorodeoxyglucose (FDG), has the potential to help in the evaluation of patients with lung cancer because the radiopharmaceutical is concentrated by metabolically active cells. We conducted a retrospective study of PET-FDG in 96 patients evaluated at our institution over the past 2 years for suspected primary pulmonary neoplasms. PET-FDG results were compared with the findings of computed tomographic scans on the same patients. All patients underwent surgical exploration with or without resection of the malignant tumors. Sites of potential malignancy were subjected to biopsy and/or excision, with subsequent pathologic evaluation.

Results: A total of 96 patients with suspected or proven primary pulmonary malignant disease were evaluated. Sixty-six patients had histologically confirmed malignant tumors, and 30 had benign masses histologically. PET-FDG had an accuracy of detecting malignancy in pulmonary lesions of 92% (sensitivity 97%; specificity 89%). A total of 111 surgically sampled sites were from lymph nodes. PET-FDG was accurate in predicting the malignancy of nodes in 91% of instances, whereas computed tomography was correct in 64%. The sensitivity, specificity, and predictive accuracy of PET in detecting metastatic lymphadenopathy in mediastinal lymph nodes were 98%, 94%, and 95%, respectively. PET-FDG also changed the M stage in 8 (12%) patients (6 with and 2 without metastases). The 6 malignant (positive) lesions were correctly identified by PET-FDG, and the 2 without tumor were accurately predicted as benign (negative).

Conclusion: These initial results suggest that PET-FDG is highly accurate in identifying and staging lung cancer. PET-FDG also appears to be more accurate in detecting metastatic mediastinal lymphadenopathy than computed tomographic scan.

PubMed Disclaimer

Publication types