Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 1998 Dec;29(6):541-50.
doi: 10.1080/10715769800300581.

Facts and artifacts in the measurement of oxidative base damage to DNA

Affiliations
Review

Facts and artifacts in the measurement of oxidative base damage to DNA

J Cadet et al. Free Radic Res. 1998 Dec.

Abstract

This short survey is aimed at critically evaluating the main available methods for measuring oxidative base damage within cellular DNA. Emphasis is placed on separative methods which are currently widely applied. These mostly concern high performance liquid chromatography (HPLC) and gas chromatography (GC) associated with sensitive detection techniques such as electrochemistry (EC) and mass spectrometry (MS). In addition, the comparison is extended to 32p-postlabeling methods, immunoassays and measurement of two main classes of oxidative DNA damage within isolated cells. It may be concluded that the HPLC-electrochemical detection (ECD) method, even if restricted to the measurement of only a few electroactive oxidized bases and nucleosides, is the simplest and safest available method at the moment. In contrast, the more versatile GC-MS method, which requires a HPLC pre-purification step in order to prevent artifactual oxidation of overwhelming normal bases to occur during derivatization, is more tedious and its sensitivity may be questionable. Alternative simpler procedures of background prevention for the GC-MS assay, which, however, remain to be validated, include low-temperature for derivatization and addition of antioxidants to the silylating reagents. Interestingly, similar levels of 8-oxo-7,8-dihydroguanine were found in cellular DNA using HPLC-ECD, HPLC-MS/MS and HPLC/32P-postlabeling methods. However, it should be noted that the level of cellular 8-oxodGuo, thus determined, is on average basis 10-fold higher than that was inferred for more indirect measurement involving the use of DNA repair enzymes with methods on isolated cells. Further efforts should be made to resolve this apparent discrepancy. In addition, the question of the biological validation of the non-invasive measurement of oxidized bases and nucleosides in urine is addressed.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources