Effects of nitinol Strecker stent placement on vascular response in normal and stenotic porcine iliac arteries
- PMID: 10102199
- DOI: 10.1016/s1051-0443(99)70039-4
Effects of nitinol Strecker stent placement on vascular response in normal and stenotic porcine iliac arteries
Abstract
Purpose: This experimental study was conducted to evaluate neointimal thickness, lumen diameters, and histologic changes in normal and stenotic porcine iliac arteries following placement of self-expanding nitinol Strecker stents.
Materials and methods: Neointimal trauma causing slight vascular stenosis was induced unilaterally within external iliac arteries of 12 swines by means of endothelial abrasion and high cholesterol diet. Nitinol Strecker stents were placed within the stenotic and the normal contralateral vascular segments. For histopathologic evaluation, the pigs were killed 12 or 24 weeks after stent placement and luminal diamters were evaluated angiographically.
Results: Excluding one occlusion, 15% narrowing of the lumen diameter was induced unilaterally (P = .002). Initial luminal gain after stent placement was greater for stenotic than for normal arteries. The amount of neointima thickness was not different between stenotic and normal vessels (P > .05). Comparing vascular diameters before stent placement and at follow-up, luminal loss due to neointima proliferation was 22% within normal arteries (P = .0002), while a luminal gain by 15% was found within the stenotic arteries (P = .008). Maturation of neointima and endothelial coverage were complete after 24 weeks.
Conclusions: Even though nitinol Strecker stents induce excessive neointimal proliferation, stenotic arteries seem to profit from great early luminal gain resulting in 15% of vascular expansion at follow-up while slight stenosis is induced within normal iliac arteries.
Similar articles
-
Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries.Circulation. 1996 Jun 15;93(12):2161-9. doi: 10.1161/01.cir.93.12.2161. Circulation. 1996. PMID: 8925585
-
Short- and long-term histopathologic evaluation of stenting using a self-expanding nitinol stent in pig carotid and iliac arteries.Catheter Cardiovasc Interv. 1999 Nov;48(3):316-23. doi: 10.1002/(sici)1522-726x(199911)48:3<316::aid-ccd19>3.0.co;2-w. Catheter Cardiovasc Interv. 1999. PMID: 10525238
-
Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.Invest Radiol. 1995 Jul;30(7):412-20. doi: 10.1097/00004424-199507000-00004. Invest Radiol. 1995. PMID: 7591650
-
Comparative pathology: radiation-induced coronary artery disease in man and animals.Semin Interv Cardiol. 1998 Sep-Dec;3(3-4):163-72. Semin Interv Cardiol. 1998. PMID: 10406688 Review.
-
Induction of vascular atrophy as a novel approach to treating restenosis. A review.J Vasc Surg. 2008 Mar;47(3):662-70. doi: 10.1016/j.jvs.2007.07.056. Epub 2007 Oct 22. J Vasc Surg. 2008. PMID: 17950562 Free PMC article. Review.
Cited by
-
Nitinol Carbofilm coated stents for peripheral applications: study in the porcine model.J Mater Sci Mater Med. 2005 Dec;16(12):1231-8. doi: 10.1007/s10856-005-4733-4. J Mater Sci Mater Med. 2005. PMID: 16362226
-
A newly designed nitinol stent: early clinical experience in the treatment of iliac artery stenoses and occlusions.Korean J Radiol. 2001 Jul-Sep;2(3):145-50. doi: 10.3348/kjr.2001.2.3.145. Korean J Radiol. 2001. PMID: 11752985 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources