Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model
- PMID: 10155102
Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model
Abstract
Restenosis persists as an important factor limiting a favorable long term outcome following mechanical revascularization. The objective of the present study was to compare the effects of an intracoronary heparin treated tantalum prototype stent and balloon angioplasty on intimal hyperplasia, luminal diameter, and thrombosis in a porcine restenosis model. Male miniswine maintained on a high cholesterol diet and 325 mg aspirin per day underwent cardiac catheterization and oversized balloon injury to the right and left circumflex coronary arteries. Two weeks later one artery was either balloon injured again or implanted with a stent. No additional anticoagulation following stent placement was given, however aspirin was continued throughout the study. At four weeks, the coronary arteries were harvested and prepared for histologic examination and blinded quantitative morphometric analysis. The prototype stent was successfully deployed in 10 coronary arteries. Histological examination at explant revealed no evidence for thrombus or platelet aggregation. The angiographic luminal diameter of stented vessels was not significantly different from the diameter measured prior to implantation. In contrast, the angiographic diameter of balloon injured vessels was significantly decreased (4.4 +/- 0.4 mm2, balloon injured, vs. 5.8 +/- 3.3 mm2, control; p < 0.05). Stented arteries showed significantly more intimal hyperplasia, compared to balloon injured vessels (2.99 +/- 0.58 mm2 intimal area, stented arteries vs. 0.38 +/- 0.15 mm2 intimal area, control arteries; p < 0.05). In conclusion, heparin treated tantalum wire prototype intracoronary stents were successfully deployed in swine coronary arteries with no evidence for thrombus formation. Despite a significant intimal response, luminal diameter was preserved in stented vessels. The data suggest that a heparin treated tantalum wire prototype intracoronary stent may be an effective method of coronary revascularization that results in the preservation of luminal diameter without thrombotic occlusion.
Similar articles
-
The effects of intravascular stents on vasomotion in porcine coronary arteries.J Invasive Cardiol. 1995 Sep;7(7):200-6. J Invasive Cardiol. 1995. PMID: 10155106
-
Coronary stenting with a novel stainless steel balloon-expandable stent: determinants of neointimal formation and changes in arterial geometry after placement in an atherosclerotic model.J Am Coll Cardiol. 1996 Apr;27(5):1270-7. doi: 10.1016/0735-1097(95)00584-6. J Am Coll Cardiol. 1996. PMID: 8609355
-
Extracellular matrix collagen synthesis and degradation following coronary balloon angioplasty.J Mol Cell Cardiol. 1996 Apr;28(4):699-706. doi: 10.1006/jmcc.1996.0065. J Mol Cell Cardiol. 1996. PMID: 8732498
-
[-Anticoagulation after intracoronary stent implantation-].Herz. 1996 Feb;21(1):60-3. Herz. 1996. PMID: 8647580 Review. German.
-
Comparative pathology: radiation-induced coronary artery disease in man and animals.Semin Interv Cardiol. 1998 Sep-Dec;3(3-4):163-72. Semin Interv Cardiol. 1998. PMID: 10406688 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical