Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Dec;7(6):557-64.
doi: 10.1111/j.1540-8183.1994.tb00496.x.

Clinical and angiographic outcome following implantation of the new Less Shortening Wallstent in aortocoronary vein grafts: introduction of a second generation stent in the clinical arena

Affiliations
Clinical Trial

Clinical and angiographic outcome following implantation of the new Less Shortening Wallstent in aortocoronary vein grafts: introduction of a second generation stent in the clinical arena

D Keane et al. J Interv Cardiol. 1994 Dec.

Abstract

One of the factors felt to have contributed to the high rate of stent occlusion in the European registry of the coronary Wallstent in the 1980s was the frequent deployment of more than one stent to cover the target lesion. This resulted from a high degree of shortening of the Wallstent upon expansion. To overcome this limitation the design of the Wallstent was modified to reduce the degree of shortening. We report the results of a study of the first patients to undergo implantation of the new Less Shortening Wallstent. Thirty-five Wallstents were electively deployed in aortocoronary vein grafts in 29 patients. Stent deployment was successful in 35 of 36 attempts in 30 lesions. In five of the 30 lesions, a second stent was required to cover the proximal portion of the lesion. Angiographic success (< 50% residual diameter stenosis as determined by off-line quantitative coronary angiography) was achieved in all 29 patients. During the in-hospital phase, no major adverse cardiac event occurred (reintervention, re-CABG, myocardial infarction, or death) and five patients had hemorrhagic complications. Following hospital discharge, one patient had a subacute stent occlusion associated with symptoms and elevated cardiac enzymes at 11 days, another patient had symptoms and elevated cardiac enzymes (CK 300 U/I) at 22 days with a patent stent, five patients required balloon angioplasty within the 6 month follow-up period (four for restenosis and one for stent occlusion), one patient underwent re-CABG for a native artery stenosis distal to the anastomosis of the patent stented vein graft.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

LinkOut - more resources