Bileaflet valve replacement: complications and costs
- PMID: 10163333
Bileaflet valve replacement: complications and costs
Abstract
A meta-analysis of the available literature on the CarboMedics and St. Jude Medical valves was conducted to compare their clinical performance. Frequency of valve-related complications for aortic, mitral, and double-valve replacements served as a measure of performance. An economic model was created to estimate the economic impact of valve-related complications. Overall, fewer events occurred with the St. Jude Medical valve than with the CarboMedics valve. As a result, use of the St. Jude Medical valve is expected to save up to $13,201 over 10 years.
Similar articles
-
Prospective randomized comparison of CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: ten-year follow-up.J Thorac Cardiovasc Surg. 2007 Mar;133(3):614-22. doi: 10.1016/j.jtcvs.2006.08.075. J Thorac Cardiovasc Surg. 2007. PMID: 17320553 Clinical Trial.
-
Twenty-year comparison of tissue and mechanical valve replacement.J Thorac Cardiovasc Surg. 2001 Aug;122(2):257-69. doi: 10.1067/mtc.2001.115238. J Thorac Cardiovasc Surg. 2001. PMID: 11479498
-
Seven-year results with the St Jude Medical Silzone mechanical prosthesis.J Thorac Cardiovasc Surg. 2009 May;137(5):1109-15.e2. doi: 10.1016/j.jtcvs.2008.07.070. J Thorac Cardiovasc Surg. 2009. PMID: 19379975
-
"Our complication rates are lower than theirs": statistical critique of heart valve comparisons.J Thorac Cardiovasc Surg. 2003 Feb;125(2):290-300. doi: 10.1067/mtc.2003.53. J Thorac Cardiovasc Surg. 2003. PMID: 12579097 Review.
-
Choice of heart valves.ASAIO Trans. 1987 Jul-Sep;33(3):90-5. ASAIO Trans. 1987. PMID: 3314941 Review. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Research Materials