Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging--initial experience
- PMID: 10207446
- DOI: 10.1148/radiology.210.2.r99fe38566
Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging--initial experience
Abstract
Gadolinium-enhanced, three-dimensional, breath-hold magnetic resonance (MR) coronary angiography was performed in two healthy volunteers and 11 patients suspected or known to have coronary artery disease. MR angiograms were compared with those obtained with retrospective respiratory gating. Of 52 main coronary arteries, 47 could be visualized with the breath-hold technique and 49 with the gating technique. Signal-to-noise and contrast-to-noise ratios were significantly higher with the breath-hold technique. Overall image quality was slightly lower with breath-hold imaging. With either technique, three of five, significant coronary stenoses were correctly identified.
Similar articles
-
Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography.Radiology. 1998 Mar;206(3):830-4. doi: 10.1148/radiology.206.3.9494509. Radiology. 1998. PMID: 9494509
-
Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography.Radiology. 2001 Apr;219(1):270-7. doi: 10.1148/radiology.219.1.r01ap37270. Radiology. 2001. PMID: 11274569
-
Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography--value of a non-electrocardiographically triggered technique.Radiology. 1998 Aug;208(2):345-51. doi: 10.1148/radiology.208.2.9680557. Radiology. 1998. PMID: 9680557
-
Coronary imaging using MRI.Herz. 1996 Apr;21(2):97-105. Herz. 1996. PMID: 8682443 Review.
-
Coronary MR angiography.Magn Reson Imaging Clin N Am. 1996 May;4(2):361-418. Magn Reson Imaging Clin N Am. 1996. PMID: 8724570 Review.
Cited by
-
MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?Neth Heart J. 2003 Jan;11(1):1-4. Neth Heart J. 2003. PMID: 25696137 Free PMC article. No abstract available.
-
Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment.Eur Radiol. 2003 Oct;13(10):2353-7. doi: 10.1007/s00330-003-2007-4. Epub 2003 Aug 2. Eur Radiol. 2003. PMID: 12904884
-
Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?Int J Cardiovasc Imaging. 2002 Dec;18(6):479-82. doi: 10.1023/a:1021108923993. Int J Cardiovasc Imaging. 2002. PMID: 12537418 No abstract available.
-
Assessment of subclinical atherosclerosis and cardiovascular risk.Clin Cardiol. 2001 Oct;24(10):642-50. doi: 10.1002/clc.4960241003. Clin Cardiol. 2001. PMID: 11594409 Free PMC article. Review.
-
Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.Invest Radiol. 2007 Oct;42(10):665-70. doi: 10.1097/RLI.0b013e3180661a77. Invest Radiol. 2007. PMID: 17984762 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources