Routine receiver operating characteristic analysis in mammography as a measure of radiologists' performance
- PMID: 10211059
- DOI: 10.1259/bjr.71.850.10211059
Routine receiver operating characteristic analysis in mammography as a measure of radiologists' performance
Abstract
A system for calculating receiver operating characteristic (ROC) curves from routine audit data is described. Both diagnostic opinion and pathology outcome data from the symptomatic mammography department were recorded in an audit database, from which ROC curves were calculated. A comparison of overall radiologists' performance was made and the appropriate performance indices discussed. Similar data were collected from the breast screening centre where the same radiologists read mammograms. The radiologists' performance in the symptomatic department was compared with that in the breast screening centre and was found to be better in the screening centre. The difference could not be wholly attributed to the different age distribution of women and highlighted the different nature of the diagnostic task and the differing sampled populations. ROC curves were drawn for different clinical signs to determine any particular area of difficulty the radiologist may experience. ROC analysis as part of routine audit can be used for maintaining and improving the quality of an individual's performance, and targeting learning on areas of particular weakness.
Similar articles
-
Medical audit of mammography: a simplified alternative.Can Assoc Radiol J. 1992 Jun;43(3):191-4. Can Assoc Radiol J. 1992. PMID: 1596762
-
Using breast radiographers' reports as a second opinion for radiologists' readings of microcalcifications in digital mammography.Br J Radiol. 2015 Mar;88(1047):20140565. doi: 10.1259/bjr.20140565. Epub 2014 Dec 23. Br J Radiol. 2015. PMID: 25536443 Free PMC article.
-
Comparison of diagnostic accuracy of breast masses using digitized images versus screen-film mammography.Acta Radiol. 2008 Jul;49(6):618-22. doi: 10.1080/02841850802014610. Acta Radiol. 2008. PMID: 18568552
-
Is radiologists' volume of mammography reading related to accuracy? A critical review of the literature.Clin Radiol. 2005 Jun;60(6):623-6. doi: 10.1016/j.crad.2005.01.011. Clin Radiol. 2005. PMID: 16038688 Review.
-
Auditing and benchmarks in screening and diagnostic mammography.Radiol Clin North Am. 2007 Sep;45(5):791-800, vi. doi: 10.1016/j.rcl.2007.07.001. Radiol Clin North Am. 2007. PMID: 17888769 Review.
Cited by
-
Evaluation of radiographers' mammography screen-reading accuracy in Australia.J Med Radiat Sci. 2015 Mar;62(1):15-22. doi: 10.1002/jmrs.59. Epub 2014 Aug 6. J Med Radiat Sci. 2015. PMID: 26229663 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical