Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Apr;3(2):94-7.
doi: 10.1016/s1091-8531(99)70077-7.

Visual acuity tests using chart, line, and single optotype in healthy and amblyopic children

Affiliations
Clinical Trial

Visual acuity tests using chart, line, and single optotype in healthy and amblyopic children

Y Morad et al. J AAPOS. 1999 Apr.

Abstract

Purpose: The purpose of this study was to evaluate the difference between full chart, single line, and single optotypes visual acuity (VA) test results in healthy and amblyopic children.

Methods: Thirty-five children with amblyopia (20 with strabismus and 15 with anisometropia) and 40 ophthalmologically normal age-matched children were examined. The mean age of the patients in the study and control groups did not differ significantly (P= .9). A commercial projector that projected tumbling-E randomly placed optotypes was used. The VA of the amblyopic eye of the patients in the study group and the right eye of the patients in the control group was examined first using a full chart of optotypes, then using a single line of optotypes, and finally with individual symbols. The procedure was repeated with the other eye.

Results: LogMAR VA improved when the full chart was substituted with a single line, and improved by a similar increment further with single optotypes, in both the study and control groups. VA improved significantly more in eyes with amblyopia than in control subjects. Results were not influenced by age.

Conclusion: VA testing using a single line gives better, sometimes misleading results, than tests with a full chart because it reduces but does not eliminate the crowding effect. When using a device that can employ more than 1 mode, the exacttest mode should be specified and maintained throughout the follow-up.