A simplified laparoscopic technique for mesh placement in ventral hernia repair
Abstract
The use of a large synthetic mesh for laparoscopic repair of significant ventral abdominal wall defects may be accompanied by technical difficulties resulting from improper orientation and positioning of the mesh over the defect. We suggest a technique based on initial fixation of the mesh center to the central point of the defect, and subsequent centrifugal attachment of the mesh to the abdominal wall. This technique is advantageous because it leads to precise orientation and positioning of the synthetic patch and to significant reduction of the time needed for its reinforcement over and around the defect.
Comment in
-
What is the appropriate mesh for laparoscopic intraperitoneal repair of abdominal wall hernia?Surg Endosc. 2000 Apr;14(4):408, author reply 409-10. doi: 10.1007/s004640000058. Surg Endosc. 2000. PMID: 10790566 No abstract available.