Low-flow vascular malformations in the head and neck: safety and feasibility of MR imaging-guided percutaneous sclerotherapy--preliminary experience with 14 procedures in three patients
- PMID: 10228544
- DOI: 10.1148/radiology.211.2.r99ma09566
Low-flow vascular malformations in the head and neck: safety and feasibility of MR imaging-guided percutaneous sclerotherapy--preliminary experience with 14 procedures in three patients
Abstract
Fourteen percutaneous sclerotherapy procedures with magnetic resonance (MR) imaging guidance were performed in three patients with low-flow vascular malformations. All targeted vascular malformation compartments were filled with sclerosing agent without complications in a mean procedural time of 29 minutes. Follow-up imaging demonstrated reduction in size of the treated portions in all patients. In conclusion, sclerotherapy with MR imaging guidance can be performed safely and allows monitoring of injection.