Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7
- PMID: 10230031
- DOI: 10.1016/s0956-5663(99)00004-4
Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7
Abstract
A flow-through amperometric immunofiltration assay system based on disposable porous filter-membranes for rapid detection of Escherichia coli O157:H7 has been developed. The analytical system utilizes flow-through, immunofiltration and enzyme immunoassay techniques in conjunction with an amperometric sensor. The parameters affecting the immunoassay such as selection of appropriate filter membranes, membrane pore size, antibody binding capacity and the concentrations of immunoreagents were investigated and optimized. Non-specific adsorption of the enzyme conjugate was investigated and minimized. A sandwich scheme of immunoassay was employed and the immunofiltration system allows to specifically and directly detect E. coli cells with a lower detection limit of 100 cells/ml. The working range is from 100 to 600 cells/ml with an overall analysis time of 30 min. No pre-enrichment was needed. This immunosensor can be easily adapted for assay of other microorganisms and may be a basis for a new class of highly sensitive bioanalytical devices for rapid quantitative detection of bacteria.
Similar articles
-
Filtration capture immunoassay for bacteria: optimization and potential for urinalysis.J Microbiol Methods. 1999 Jun;36(3):157-65. doi: 10.1016/s0167-7012(99)00027-5. J Microbiol Methods. 1999. PMID: 10379802
-
Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7.Biosens Bioelectron. 2008 Jul 15;23(12):1832-7. doi: 10.1016/j.bios.2008.02.030. Epub 2008 Mar 14. Biosens Bioelectron. 2008. PMID: 18424027
-
Ultrasensitive detection of E. coli O157:H7 with biofunctional magnetic bead concentration via nanoporous membrane based electrochemical immunosensor.Biosens Bioelectron. 2013 Mar 15;41:532-7. doi: 10.1016/j.bios.2012.09.016. Epub 2012 Sep 19. Biosens Bioelectron. 2013. PMID: 23058659
-
An immunofiltration strip method based on the photothermal effect of gold nanoparticles for the detection of Escherichia coli O157:H7.Analyst. 2019 Jan 14;144(2):573-578. doi: 10.1039/c8an01004h. Analyst. 2019. PMID: 30427329
-
Development of a low-cost paper-based ELISA method for rapid Escherichia coli O157:H7 detection.Anal Biochem. 2018 Feb 1;542:58-62. doi: 10.1016/j.ab.2017.11.010. Epub 2017 Nov 20. Anal Biochem. 2018. PMID: 29158131 Review.
Cited by
-
Low Temperature Reactive Sputtering of Thin Aluminum Nitride Films on Metallic Nanocomposites.PLoS One. 2015 Jul 20;10(7):e0133479. doi: 10.1371/journal.pone.0133479. eCollection 2015. PLoS One. 2015. PMID: 26193701 Free PMC article.
-
An Intact Cell Bioluminescence-Based Assay for the Simple and Rapid Diagnosis of Urinary Tract Infection.Int J Mol Sci. 2020 Jul 16;21(14):5015. doi: 10.3390/ijms21145015. Int J Mol Sci. 2020. PMID: 32708609 Free PMC article.
-
A novel and highly specific phage endolysin cell wall binding domain for detection of Bacillus cereus.Eur Biophys J. 2015 Sep;44(6):437-46. doi: 10.1007/s00249-015-1044-7. Epub 2015 Jun 5. Eur Biophys J. 2015. PMID: 26043681
-
Serum creatinine detection by a conducting-polymer-based electrochemical sensor to identify allograft dysfunction.Anal Chem. 2012 Sep 18;84(18):7933-7. doi: 10.1021/ac3016888. Epub 2012 Aug 24. Anal Chem. 2012. PMID: 22881369 Free PMC article.
-
Quantum dot enabled detection of Escherichia coli using a cell-phone.Analyst. 2012 Jun 7;137(11):2541-4. doi: 10.1039/c2an35071h. Epub 2012 Mar 7. Analyst. 2012. PMID: 22396952 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources