18F-FDG PET studies in patients with extratemporal and temporal epilepsy: evaluation of an observer-independent analysis
- PMID: 10319744
18F-FDG PET studies in patients with extratemporal and temporal epilepsy: evaluation of an observer-independent analysis
Abstract
The aim of this study was to evaluate an observer-independent analysis of 18F-fluorodeoxyglucose (FDG) PET studies in patients with temporal or extratemporal epilepsy.
Methods: Twenty-seven patients with temporal epilepsy and 22 patients with extratemporal epilepsy were included in the study. All patients with temporal epilepsy and 7 patients with extratemporal epilepsy underwent surgical treatment. In patients who showed significant postoperative improvement (temporal, n = 23; extratemporal, n = 6), the epileptogenic focus was assumed to be located in the area of surgical resection. In extratemporal epilepsy patients who did not undergo surgery, the focus localization was determined using a combination of semiology, ictal and interictal electroencephalography, [99mTc]ethyl cysteinate dimer SPECT, MRI and [11C]flumazenil PET. Visual analysis was performed by two experienced and two less experienced blinded observers using sagittal, axial and coronal images. In the automated analysis after anatomic standardization and generation of three-dimensional stereotactic surface projections (SSPs), a pixelwise comparison of 18F-FDG uptake with an age-matched reference database (n = 20) was performed, resulting in z score images. Pixels with the maximum deviation were detected, summarized and attached to one of 20 predefined surface regions of interest. For comparison with 18F-FDG PET and MR images, three-dimensional overlay images were generated.
Results: In patients with temporal epilepsy, the sensitivity was comparable for visual and observer-independent analysis (three-dimensional SSP 86%, experienced observers 86%-90%, less experienced observers 77%-86%). In patients with extratemporal epilepsy, three-dimensional SSP showed a significantly higher sensitivity in detecting the epileptogenic focus (67%) than did visual analysis (experienced 33%-38%, each less experienced 19%). In temporal lobe epilepsy, there was moderate to good agreement between the localization found with three-dimensional SSP and the different observers. In patients with extratemporal epilepsy, there was a high interobserver variability and only a weak agreement between the localization found with three-dimensional SSP and the different observers. Although three-dimensional SSP detected multiple lesions more often than visual analysis, the determination of the highest deviation from the reference database allowed the identification of the epileptogenic focus with a higher accuracy than subjective criteria, especially in extratemporal epilepsy.
Conclusion: Three-dimensional SSP increases sensitivity and reduces observer variability of the analysis of 18F-FDG PET images in patients with extratemporal epilepsy and is, therefore, a useful tool in the evaluation of this patient group. The benefit of this analytical approach in patients with temporal epilepsy is less apparent.
Similar articles
-
Pre-surgical identification of epileptogenic areas in temporal lobe epilepsy by 123I-iomazenil SPECT: a comparison with IMP SPECT and FDG PET.Nucl Med Commun. 2006 Nov;27(11):893-9. doi: 10.1097/01.mnm.0000243380.79872.32. Nucl Med Commun. 2006. PMID: 17021430 Clinical Trial.
-
Is 11C-flumazenil PET superior to 18FDG PET and 123I-iomazenil SPECT in presurgical evaluation of temporal lobe epilepsy?J Neurol Neurosurg Psychiatry. 1997 Feb;62(2):141-50. doi: 10.1136/jnnp.62.2.141. J Neurol Neurosurg Psychiatry. 1997. PMID: 9048714 Free PMC article.
-
Diagnostic Performance of Positron Emission Tomography for the Presurgical Evaluation of Patients with Non-lesional Intractable Partial Epilepsy: Comparison among 18F-FDG, 11C-Flumazenil, and 11C-Flumazenil Binding Potential Imaging Using Statistical Imaging Analysis.Hiroshima J Med Sci. 2015 Dec;64(4):51-7. Hiroshima J Med Sci. 2015. PMID: 26964154
-
Neuronuclear assessment of patients with epilepsy.Semin Nucl Med. 2008 Jul;38(4):227-39. doi: 10.1053/j.semnuclmed.2008.02.004. Semin Nucl Med. 2008. PMID: 18514079 Review.
-
[PET and SPECT in epilepsy].Rev Esp Med Nucl Imagen Mol. 2014 May-Jun;33(3):165-74. doi: 10.1016/j.remn.2014.01.001. Epub 2014 Feb 22. Rev Esp Med Nucl Imagen Mol. 2014. PMID: 24565567 Review. Spanish.
Cited by
-
The promise of subtraction ictal SPECT co-registered to MRI for improved seizure localization in pediatric epilepsies: Affecting factors and relationship to the surgical outcome.Epilepsy Res. 2017 Jan;129:59-66. doi: 10.1016/j.eplepsyres.2016.11.020. Epub 2016 Nov 30. Epilepsy Res. 2017. PMID: 27918961 Free PMC article.
-
Quantitative Rodent Brain Receptor Imaging.Mol Imaging Biol. 2020 Apr;22(2):223-244. doi: 10.1007/s11307-019-01368-9. Mol Imaging Biol. 2020. PMID: 31168682 Review.
-
¹⁸F-FDG PET for the early diagnosis of Alzheimer's disease dementia and other dementias in people with mild cognitive impairment (MCI).Cochrane Database Syst Rev. 2015 Jan 28;1(1):CD010632. doi: 10.1002/14651858.CD010632.pub2. Cochrane Database Syst Rev. 2015. PMID: 25629415 Free PMC article.
-
Positron Emission Tomography and Magnetic Resonance Imaging of the Brain in Fabry Disease: A Nationwide, Long-Time, Prospective Follow-Up.PLoS One. 2015 Dec 2;10(12):e0143940. doi: 10.1371/journal.pone.0143940. eCollection 2015. PLoS One. 2015. PMID: 26629990 Free PMC article.
-
The role of functional neuroimaging in pre-surgical epilepsy evaluation.Front Neurol. 2014 Mar 24;5:31. doi: 10.3389/fneur.2014.00031. eCollection 2014. Front Neurol. 2014. PMID: 24715886 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical