Factors in the reproducibility of electromyographic power spectrum analysis of lumbar paraspinal muscle fatigue
- PMID: 10327510
- DOI: 10.1097/00007632-199905010-00009
Factors in the reproducibility of electromyographic power spectrum analysis of lumbar paraspinal muscle fatigue
Abstract
Study design: An investigation of the reliability of various factors used to analyze electromyograms of paraspinal muscles of the lumbar spine.
Objectives: To determine the reproducibility of several electromyographic variables over time and to assess the influence of confounding factors.
Summary of background data: Previous reliability studies have included small numbers of subjects and often have not explored the factors that can influence the reliability of this technique.
Methods: In the first study, 39 volunteers underwent electromyographic tests on three occasions at two loads. The time interval was 1 week between tests. Electromyographic variables measured included half-width (spectral width at half maximum amplitude), initial median frequency, median frequency slope, initial root mean square, root mean square, and root mean square slope. In the second study to determine the influence of posture, nine volunteers were tested on two occasions with a change in posture between tests.
Results: Reliability was better for tests at the higher loads. Initial median frequency, half-width, and root mean square all had acceptable reproducibility over time, with a coefficient of variation less than 10. Initial median frequency and half-width proved to be the most suitable variables; they yielded the largest between-subject variation and, of all variables, were affected the least by changes in load. The remaining variables were very load-dependent. A change in posture greatly influenced the reproducibility.
Conclusion: These results demonstrate that only initial median frequency and half-width have acceptable reproducibility over time and at different loads, with the potential to be useful in discriminating between individuals. Changes in posture can greatly change an electromyographic result.
Similar articles
-
Between-days reliability of electromyographic measures of paraspinal muscle fatigue at 40, 50 and 60% levels of maximal voluntary contractile force.Clin Rehabil. 2002 Nov;16(7):761-71. doi: 10.1191/0269215502cr551oa. Clin Rehabil. 2002. PMID: 12428825
-
The effect of back belt use on isometric lifting force and fatigue of the lumbar paraspinal muscles.Spine (Phila Pa 1976). 1998 Oct 1;23(19):2104-9. doi: 10.1097/00007632-199810010-00013. Spine (Phila Pa 1976). 1998. PMID: 9794055 Clinical Trial.
-
Back and hip extensor muscles fatigue in healthy subjects: task-dependency effect of two variants of the Sorensen test.Eur Spine J. 2008 Dec;17(12):1721-6. doi: 10.1007/s00586-008-0782-y. Epub 2008 Sep 24. Eur Spine J. 2008. PMID: 18813961 Free PMC article.
-
Paraspinal muscle activities of patients with scoliosis after spine fusion: an electromyographic study.Spine (Phila Pa 1976). 2002 Jun 1;27(11):1180-5. doi: 10.1097/00007632-200206010-00009. Spine (Phila Pa 1976). 2002. PMID: 12045515 Clinical Trial.
-
The assessment of back muscle capacity using intermittent static contractions. Part I - Validity and reliability of electromyographic indices of fatigue.J Electromyogr Kinesiol. 2008 Dec;18(6):1006-19. doi: 10.1016/j.jelekin.2007.03.012. Epub 2007 Jul 20. J Electromyogr Kinesiol. 2008. PMID: 17643316 Review.
Cited by
-
The Application of Surface Electromyography Technology in Evaluating Paraspinal Muscle Function.Diagnostics (Basel). 2024 May 24;14(11):1086. doi: 10.3390/diagnostics14111086. Diagnostics (Basel). 2024. PMID: 38893614 Free PMC article. Review.
-
The use of non-amplitude components of the myoelectric signal in identifying differences in function between the low back injured and controls.J Can Chiropr Assoc. 2004 Sep;48(3):225-34. J Can Chiropr Assoc. 2004. PMID: 17549122 Free PMC article.
-
EMG analysis of lumbar paraspinal muscles as a predictor of the risk of low-back pain.Eur Spine J. 2010 Jul;19(7):1145-52. doi: 10.1007/s00586-010-1277-1. Epub 2010 Feb 2. Eur Spine J. 2010. PMID: 20127260 Free PMC article.
-
The potential use of spectral electromyographic fatigue as a screening and outcome monitoring tool of sarcopenic back muscle alterations.J Neuroeng Rehabil. 2014 Jul 2;11:106. doi: 10.1186/1743-0003-11-106. J Neuroeng Rehabil. 2014. PMID: 24985941 Free PMC article.
-
Properties of Force Output and Spectral EMG in Young Patients with Nonspecific Low Back Pain during Isometric Trunk Extension.J Phys Ther Sci. 2014 Mar;26(3):323-9. doi: 10.1589/jpts.26.323. Epub 2014 Mar 25. J Phys Ther Sci. 2014. PMID: 24707077 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials