Asymmetric adiabatic pulses for NH selection
- PMID: 10329242
- DOI: 10.1006/jmre.1999.1713
Asymmetric adiabatic pulses for NH selection
Abstract
Many types of NMR experiments demand the use of frequency-selective pulses to invert magnetization within discrete frequency limits. For certain experiments, only one side of the inversion band must be sharply demarcated, in which case this transition bandwidth can be narrowed when using an asymmetric adiabatic full passage. In the present study, a highly efficient asymmetric adiabatic full passage was created from a combination of two adiabatic half passages which used different modulation functions (HS12 and tanh/tan). Each adiabatic half passage occupied a different amount of time in the total pulse and performed one-half of the inversion. On one side, HS12 produced a sharp transition between inverted and noninverted states which was approximately 2.5 times narrower than the transition bandwidth afforded by a symmetric hyperbolic secant pulse of equal length. On the other side of the narrow transition band, the tanh/tan pulse achieved broadband inversion. These asymmetric pulses were applied to select NH groups immediately adjacent to the water signal in water-flip-back HSQC experiments using a double spin echo for the reverse INEPT step.
Copyright 1999 Academic Press.
Similar articles
-
Compensated adiabatic inversion pulses: broadband INEPT and HSQC.J Magn Reson. 2007 Aug;187(2):258-65. doi: 10.1016/j.jmr.2007.05.009. Epub 2007 May 17. J Magn Reson. 2007. PMID: 17533143
-
Design of selective adiabatic inversion pulses using the adiabatic condition.J Magn Reson. 1997 Dec;129(2):115-24. doi: 10.1006/jmre.1997.1263. J Magn Reson. 1997. PMID: 9441875
-
Evolution strategy optimization for adiabatic pulses in MRI.J Magn Reson. 1999 May;138(1):48-53. doi: 10.1006/jmre.1998.1677. J Magn Reson. 1999. PMID: 10329225
-
Principles of MR image formation and reconstruction.Magn Reson Imaging Clin N Am. 1999 Nov;7(4):629-59. Magn Reson Imaging Clin N Am. 1999. PMID: 10631672 Review.
-
Adiabatic pulses.NMR Biomed. 1997 Dec;10(8):423-34. doi: 10.1002/(sici)1099-1492(199712)10:8<423::aid-nbm488>3.0.co;2-x. NMR Biomed. 1997. PMID: 9542739 Review.
Cited by
-
Simultaneous detection of metabolite concentration changes, water BOLD signal and pH changes during visual stimulation in the human brain at 9.4T.J Cereb Blood Flow Metab. 2022 Jun;42(6):1104-1119. doi: 10.1177/0271678X221075892. Epub 2022 Jan 21. J Cereb Blood Flow Metab. 2022. PMID: 35060409 Free PMC article.
-
Prospective motion correction for cervical spinal cord MRS.Magn Reson Med. 2024 Jan;91(1):19-27. doi: 10.1002/mrm.29836. Epub 2023 Sep 29. Magn Reson Med. 2024. PMID: 37772616 Free PMC article.
-
Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain.Magn Reson Med. 2010 Sep;64(3):638-44. doi: 10.1002/mrm.22546. Magn Reson Med. 2010. PMID: 20632402 Free PMC article.
-
Quantification of NAD+ in human brain with 1 H MR spectroscopy at 3 T: Comparison of three localization techniques with different handling of water magnetization.Magn Reson Med. 2022 Sep;88(3):1027-1038. doi: 10.1002/mrm.29267. Epub 2022 May 8. Magn Reson Med. 2022. PMID: 35526238 Free PMC article.
-
Metabolite cycled liver 1 H MRS on a 7 T parallel transmit system.NMR Biomed. 2020 Aug;33(8):e4343. doi: 10.1002/nbm.4343. Epub 2020 Jun 8. NMR Biomed. 2020. PMID: 32515151 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical