Oscillations in the human cutaneous blood perfusion signal modified by endothelium-dependent and endothelium-independent vasodilators
- PMID: 10329256
- DOI: 10.1006/mvre.1998.2139
Oscillations in the human cutaneous blood perfusion signal modified by endothelium-dependent and endothelium-independent vasodilators
Abstract
The purpose of the present study was to compare the effects of endothelium-dependent [acetylcholine (ACh)] and endothelium-independent [sodium nitroprusside (SNP)] vasodilators on the oscillatory components of the cutaneous blood perfusion signals in humans. The unstimulated basal blood perfusion and the blood perfusion during iontophoretically delivered ACh and SNP were measured using laser Doppler flowmetry (LDF). The wavelet transform was calculated before spectral analysis of the measured signals. In the frequency interval from 0.0095 to 1.6 Hz the LDF signal consists of oscillations with five different characteristic frequencies. In addition to the cardiac (1 Hz) and respiratory (0.3 Hz) rhythms, three other oscillations in the regions around 0.1, 0.04, and 0.01 Hz were detected. The oscillations with the different frequencies were observed in unstimulated blood flow and also during stimulation with ACh and SNP. Compared to the unstimulated blood flow, both ACh and SNP increased the mean amplitude of the total spectrum (P < 0. 005 for both substances). The only significant difference between the effects of ACh and SNP was observed in the amplitude of oscillations with the frequency of around 0.01 Hz. ACh increased the absolute amplitude of this frequency to a greater extent than SNP in athletes (P = 0.03), whereas only a trend was observed in controls (P = 0.2). The relative amplitude, defined as the ratio between the absolute amplitude of a particular frequency interval and the mean amplitude of the total spectrum, was also higher for ACh compared to SNP both in controls (P = 0.008) and in athletes (P = 0.004), only for oscillations with the frequency of around 0.01 Hz. We conclude that ACh selectively influences the oscillatory component of around 0.01 Hz in the cutaneous blood perfusion signal to a greater extent than SNP. This finding indicates that endothelium-mediated vasodilatation is manifested as oscillations with a repetition time of approximately 1 min. The mechanisms for the endothelial dependency of this frequency remain to be elucidated. Our data indicate that spectral analysis based on wavelet transform of the cutaneous perfusion signal can be used clinically to investigate endothelial function. The described noninvasive method might be used to evaluate endothelial function for research, for diagnostic purposes, and maybe also to assess effects of therapy in cardiovascular diseases.
Copyright 1999 Academic Press.
Similar articles
-
Low-frequency oscillations of the laser Doppler perfusion signal in human skin.Microvasc Res. 2006 Nov;72(3):120-7. doi: 10.1016/j.mvr.2006.05.006. Epub 2006 Jul 18. Microvasc Res. 2006. PMID: 16854436
-
Generalised wavelet analysis of cutaneous flowmotion during post-occlusive reactive hyperaemia in patients with peripheral arterial obstructive disease.Biomed Pharmacother. 2005 Jun;59(5):233-9. doi: 10.1016/j.biopha.2004.01.008. Biomed Pharmacother. 2005. PMID: 15925479
-
Spectral analysis of the laser Doppler perfusion signal in human skin before and after exercise.Microvasc Res. 1998 Nov;56(3):173-82. doi: 10.1006/mvre.1998.2108. Microvasc Res. 1998. PMID: 9828155
-
Non-invasive assessment of skin microvascular function in humans: an insight into methods.Microcirculation. 2012 Jan;19(1):47-64. doi: 10.1111/j.1549-8719.2011.00129.x. Microcirculation. 2012. PMID: 21883640 Review.
-
Wavelet analysis of laser Doppler microcirculatory signals: Current applications and limitations.Front Physiol. 2023 Jan 20;13:1076445. doi: 10.3389/fphys.2022.1076445. eCollection 2022. Front Physiol. 2023. PMID: 36741808 Free PMC article. Review.
Cited by
-
The phase coherence of the neurovascular unit is reduced in Huntington's disease.Brain Commun. 2024 Jun 10;6(3):fcae166. doi: 10.1093/braincomms/fcae166. eCollection 2024. Brain Commun. 2024. PMID: 38938620 Free PMC article.
-
Fluid transport in the brain.Physiol Rev. 2022 Apr 1;102(2):1025-1151. doi: 10.1152/physrev.00031.2020. Epub 2021 May 5. Physiol Rev. 2022. PMID: 33949874 Free PMC article. Review.
-
Coupling and dynamics of cortical and autonomic signals are linked to central inhibition during the wake-sleep transition.Sci Rep. 2017 Sep 18;7(1):11804. doi: 10.1038/s41598-017-09513-6. Sci Rep. 2017. PMID: 28924202 Free PMC article.
-
Evaluation of microvascular reactivity with laser Doppler flowmetry in chronic kidney disease.World J Nephrol. 2013 Aug 6;2(3):77-83. doi: 10.5527/wjn.v2.i3.77. World J Nephrol. 2013. PMID: 24255889 Free PMC article. Review.
-
Characterizing Vascular Dysfunction in Genetically Modified Mice through the Hyperoxia Model.Int J Mol Sci. 2019 May 2;20(9):2178. doi: 10.3390/ijms20092178. Int J Mol Sci. 2019. PMID: 31052504 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources