Specific absorption rates and induced current densities for an anatomy-based model of the human for exposure to time-varying magnetic fields of MRI
- PMID: 10332859
- DOI: 10.1002/(sici)1522-2594(199904)41:4<816::aid-mrm22>3.0.co;2-5
Specific absorption rates and induced current densities for an anatomy-based model of the human for exposure to time-varying magnetic fields of MRI
Abstract
A 6-mm resolution, 30-tissue anatomy-based model of the human body is used to calculate specific absorption rate (SAR) and the induced current density distributions for radiofrequency and switched gradient magnetic fields used for MRI, respectively. For SAR distributions, the finite-difference time-domain (FDTD) method is used including modeling of 16-conductor birdcage coils and outer shields of dimensions that are typical of body and head coils and a new high-frequency head coil proposed for the 300-400 MHz band. SARs at 64, 128, and 170 MHz have been found to increase with frequency (f) as f(k) where k is on the order of 1.1-1.2. The tables of the calculated maximum 1 kg and 100 g SAR may be used to calculate the maximum RF currents and/or magnetic fields that may be used in order not to exceed the safety guidelines. Because of the low frequencies associated with switched gradient magnetic fields, a quasi-static impedance method is used for calculation of induced current densities that are compared with the safety guidelines.
Similar articles
-
On the SAR and field inhomogeneity of birdcage coils loaded with the human head.Magn Reson Med. 1997 Dec;38(6):953-63. doi: 10.1002/mrm.1910380615. Magn Reson Med. 1997. PMID: 9402197
-
Currents induced in anatomic models of the human for uniform and nonuniform power frequency magnetic fields.Bioelectromagnetics. 2001 Feb;22(2):112-21. Bioelectromagnetics. 2001. PMID: 11180257
-
Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head.IEEE Trans Biomed Eng. 1998 May;45(5):650-9. doi: 10.1109/10.668756. IEEE Trans Biomed Eng. 1998. PMID: 9581064
-
Numerical dosimetry at power-line frequencies using anatomically based models.Bioelectromagnetics. 1992;Suppl 1:43-60. doi: 10.1002/bem.2250130706. Bioelectromagnetics. 1992. PMID: 1285721 Review.
-
SAR Simulations & Safety.Neuroimage. 2018 Mar;168:33-58. doi: 10.1016/j.neuroimage.2017.03.035. Epub 2017 Mar 20. Neuroimage. 2018. PMID: 28336426 Review.
Cited by
-
Radiofrequency heating at 9.4T: in vivo temperature measurement results in swine.Magn Reson Med. 2008 Jan;59(1):73-8. doi: 10.1002/mrm.21425. Magn Reson Med. 2008. PMID: 17969077 Free PMC article.
-
Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.IEEE Trans Med Imaging. 2010 Apr;29(4):1029-38. doi: 10.1109/TMI.2010.2040624. Epub 2010 Mar 22. IEEE Trans Med Imaging. 2010. PMID: 20335090 Free PMC article.
-
Average SAR prediction, validation, and evaluation for a compact MR scanner head-sized RF coil.Magn Reson Imaging. 2022 Jan;85:168-176. doi: 10.1016/j.mri.2021.10.011. Epub 2021 Oct 16. Magn Reson Imaging. 2022. PMID: 34666159 Free PMC article.
-
Direct SAR mapping by thermoacoustic imaging: A feasibility study.Magn Reson Med. 2017 Oct;78(4):1599-1606. doi: 10.1002/mrm.26517. Epub 2016 Oct 25. Magn Reson Med. 2017. PMID: 27779779 Free PMC article.
-
The ultimate signal-to-noise ratio in realistic body models.Magn Reson Med. 2017 Nov;78(5):1969-1980. doi: 10.1002/mrm.26564. Epub 2016 Dec 4. Magn Reson Med. 2017. PMID: 27917528 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous