Aortic stump tailoring with GRF glue and a felt strip
Abstract
We describe herein a new technique of aortic stump tailoring for aortic dissection. This method involves the application of gelatine-resorcin-formalin (GRF) glue and a felt strip, with manipulation using the balloon of an endotracheal tube. The conjoined wall consists of three layers, but it is completed like a single layer. This procedure facilitates anastomosis to the graft in the next step.
Similar articles
-
[Surgical treatment of dissecting aortic aneurysm using GRF glue].Kyobu Geka. 1992 Sep;45(10):883-5. Kyobu Geka. 1992. PMID: 1518201 Japanese.
-
Glue containment and anastomosis reinforcement in repair of aortic dissection.Ann Thorac Surg. 1999 May;67(5):1510-1. doi: 10.1016/s0003-4975(99)00229-5. Ann Thorac Surg. 1999. PMID: 10355455
-
[Surgery for acute aortic dissection extending to the aortic root using gelatine-resorcine-formol biological glue--a case report].Nihon Kyobu Geka Gakkai Zasshi. 1997 Jul;45(7):1024-7. Nihon Kyobu Geka Gakkai Zasshi. 1997. PMID: 9256644 Japanese.
-
The use of surgical glue in acute type A aortic dissection.Gen Thorac Cardiovasc Surg. 2014 Apr;62(4):207-13. doi: 10.1007/s11748-013-0343-0. Epub 2013 Nov 21. Gen Thorac Cardiovasc Surg. 2014. PMID: 24254987 Review.
-
Surgery for acute aortic dissection using gelatin-resorcin-formalin glue: perspective from 10 years of follow-up at a single center.J Artif Organs. 2008;11(1):19-23. doi: 10.1007/s10047-007-0402-3. Epub 2008 Apr 15. J Artif Organs. 2008. PMID: 18414988 Review.