Estimation of blood perfusion using ultrasound
- PMID: 10333683
- DOI: 10.1243/0954411991534834
Estimation of blood perfusion using ultrasound
Abstract
Ways to measure blood perfusion using ultrasound techniques such as continuous-wave Doppler, pulsed Doppler, colour Doppler and power Doppler will be reviewed. From a certain standpoint, blood perfusion may be defined as the difference between arterial inflow and arterial outflow from a considered volume, i.e. capillary flow. The low velocities and small blood volumes involved make the signal-to-noise ratio, dynamic range and frequency resolution critical factors in the detection system. Another limiting factor is tissue motion which obscures the blood signal. Perfusion may still under certain conditions be estimated with the first moment of the Doppler power spectrum, as obtained with any Doppler ultrasound method. Modern flow mapping techniques also make it possible to estimate perfusion by counting the number of pixels that indicate flow, but low flow velocities cannot be included in the estimate. Future high-frequency systems may, however, provide very detailed images of minute flow distributions in superficial layers. Contrast agents are widely used today to enhance the blood signal, and a technique named harmonic imaging can suppress movement artefacts from surrounding tissue. Transient signals from disrupting contrast agent particles in an ultrasound field can potentially be used for perfusion quantification. Future developments to extract the blood flow signal from its noisy environment, aside from contrast agents, may be multiple sample volumes, frequency compounding and/or improved signal processing. The lack of an adequate perfusion phantom for verification of measurements of microcirculatory flow becomes, however, more apparent with improved detectability of slow flows.
Similar articles
-
Simulated capillary blood flow measurement using a nonlinear ultrasonic contrast agent.Ultrason Imaging. 1992 Apr;14(2):134-58. doi: 10.1177/016173469201400204. Ultrason Imaging. 1992. PMID: 1604755
-
Movement artefact suppression in blood perfusion measurements using a multifrequency technique.Ultrasound Med Biol. 2002 Jan;28(1):69-79. doi: 10.1016/s0301-5629(01)00476-8. Ultrasound Med Biol. 2002. PMID: 11879954
-
Measurement of blood perfusion in tissue using Doppler ultrasound.Ultrasound Med Biol. 1991;17(5):433-44. doi: 10.1016/0301-5629(91)90179-z. Ultrasound Med Biol. 1991. PMID: 1835810
-
Ultrasonic colour flow imaging.Phys Med Biol. 1994 Dec;39(12):2113-45. doi: 10.1088/0031-9155/39/12/001. Phys Med Biol. 1994. PMID: 15551544 Review.
-
Ultrasonic investigation of blood flow.Proc Inst Mech Eng H. 1999;213(3):169-80. doi: 10.1243/0954411991534898. Proc Inst Mech Eng H. 1999. PMID: 10420772 Review.
Cited by
-
Endogenous progesterone in unexplained infertility: a systematic review and meta-analysis.J Assist Reprod Genet. 2023 Mar;40(3):509-524. doi: 10.1007/s10815-022-02689-5. Epub 2022 Dec 27. J Assist Reprod Genet. 2023. PMID: 36572790 Free PMC article.
-
Application and prospects of AI-based radiomics in ultrasound diagnosis.Vis Comput Ind Biomed Art. 2023 Oct 13;6(1):20. doi: 10.1186/s42492-023-00147-2. Vis Comput Ind Biomed Art. 2023. PMID: 37828411 Free PMC article. Review.
-
[Vascular imaging with contrast-enhanced sonography for experimental use].Radiologe. 2005 Jun;45(6):552-9. doi: 10.1007/s00117-005-1186-1. Radiologe. 2005. PMID: 15809842 Review. German.
-
Evaluation of antral follicle growth in the macaque ovary during the menstrual cycle and controlled ovarian stimulation by high-resolution ultrasonography.Am J Primatol. 2009 May;71(5):384-92. doi: 10.1002/ajp.20664. Am J Primatol. 2009. PMID: 19189308 Free PMC article.
-
Vector-flow imaging of slowly moving ex vivo blood with photoacoustics and pulse-echo ultrasound.Photoacoustics. 2024 Mar 15;38:100602. doi: 10.1016/j.pacs.2024.100602. eCollection 2024 Aug. Photoacoustics. 2024. PMID: 39687629 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources