An ex vivo investigation into the bond strength of orthodontic brackets and adhesive systems
- PMID: 10333887
- DOI: 10.1093/ortho/26.1.47
An ex vivo investigation into the bond strength of orthodontic brackets and adhesive systems
Abstract
The aim of this study was to compare the shear bond strength of Adhesive Precoated Brackets (APC) with that of two types of uncoated bracket bases, Straight-Wire and Dyna-Lock. Two types of orthodontic adhesives were used, Transbond XT and Right-On. Three different curing times were evaluated with the APC brackets in order to find the best. Adhesive remnants on the enamel surface following debond were evaluated using the Adhesive Remnant Index (Artun and Bergland, 1984). Bond strengths ranged from 11.00 to 22.08 MPa. For both types of brackets Transbond produced a significant increase in bond strength compared to Right-On. The Dyna-Lock/Right-On combination produced the poorest results. APC brackets cured for 40 s had similar bond strengths to uncoated brackets fixed by means of Transbond. Overall, 79 per cent of specimens had less than half the tooth surface covered with adhesive following debond. Significantly more adhesive remained on tooth surfaces following debond of the Straight-Wire/Right-On group than any other bracket/adhesive combination. Bond strengths were higher with light-cured Transbond than with chemically-cured Right-On. When Transbond is used in association with APC brackets a 40-second cure time is recommended.
Similar articles
-
Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial.Br J Orthod. 1998 Nov;25(4):283-7. doi: 10.1093/ortho/25.4.283. Br J Orthod. 1998. PMID: 9884779 Clinical Trial.
-
Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study.Eur J Orthod. 2006 Aug;28(4):400-4. doi: 10.1093/ejo/cji107. Epub 2006 Feb 22. Eur J Orthod. 2006. PMID: 16495372 Clinical Trial.
-
Effects of modifying the adhesive composition on the bond strength of orthodontic brackets.Angle Orthod. 2002 Oct;72(5):464-7. doi: 10.1043/0003-3219(2002)072<0464:EOMTAC>2.0.CO;2. Angle Orthod. 2002. PMID: 12401056
-
Adhesive precoated bracket systems and operator coated bracket systems: Is there any difference? A systematic review and meta-analysis.Angle Orthod. 2019 May;89(3):495-504. doi: 10.2319/051818-373.1. Epub 2018 Dec 17. Angle Orthod. 2019. PMID: 30556748 Free PMC article.
-
Assessment of in vivo bond strength studies of the orthodontic bracket-adhesive system: A systematic review.Eur J Dent. 2018 Oct-Dec;12(4):602-609. doi: 10.4103/ejd.ejd_22_18. Eur J Dent. 2018. PMID: 30369810 Free PMC article. Review.
Cited by
-
Comparative in-vivo bond failure rate of orthodontic brackets when bracket base is treated with micro-abrasive blasting vs. acid etching: eighteen month randomized control trial and scanning electron microscope study.PeerJ. 2024 Jun 28;12:e17645. doi: 10.7717/peerj.17645. eCollection 2024. PeerJ. 2024. PMID: 38952970 Free PMC article. Clinical Trial.
-
In vitro evaluation of shear bond strength of orthodontic stainless steel brackets using transillumination.J Clin Exp Dent. 2018 May 1;10(5):e450-e457. doi: 10.4317/jced.54751. eCollection 2018 May. J Clin Exp Dent. 2018. PMID: 29849969 Free PMC article.
-
Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets.J Clin Exp Dent. 2013 Oct 1;5(4):e197-202. doi: 10.4317/jced.51113. eCollection 2013 Oct 1. J Clin Exp Dent. 2013. PMID: 24455081 Free PMC article.
-
Shear bond strength of orthodontic color-change adhesives with different light-curing times.Dent Res J (Isfahan). 2015 May-Jun;12(3):265-70. Dent Res J (Isfahan). 2015. PMID: 26005468 Free PMC article.
-
Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth.Prog Orthod. 2013 Nov 21;14:49. doi: 10.1186/2196-1042-14-49. Prog Orthod. 2013. PMID: 24325795 Free PMC article.