. 1999 Jun;83(6):718-22.
doi: 10.1136/bjo.83.6.718.

Selective laser trabeculoplasty v argon laser trabeculoplasty: a prospective randomised clinical trial

Affiliations
Clinical Trial

Selective laser trabeculoplasty v argon laser trabeculoplasty: a prospective randomised clinical trial

K F Damji et al. Br J Ophthalmol. 1999 Jun.

Abstract

Aims: To compare the effectiveness of selective laser trabeculoplasty (SLT, a 532 nm Nd:YAG laser) with argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with medically uncontrolled open angle glaucoma.

Methods: A prospective randomised clinical trial was designed. Patients were randomised to treatment with either SLT or ALT and were evaluated at 1 hour, 1 week, 1, 3, and 6 months post-laser.

Results: There were 18 eyes in each group. Baseline characteristics were similar in both groups. In the SLT group the mean IOP at baseline, 1, 3, and 6 months was 22.8 (SD 3.0), 20.1 (4.6), 19.3 (6.0), and 17.8 (4.8) mm Hg, respectively. In the ALT group, the mean IOP at baseline, 1, 3, and 6 months was 22.5 (3.6), 19.5 (4.7), 19.6 (5.6), and 17.7 (3.3) mm Hg, respectively. There was a greater anterior chamber reaction, 1 hour after SLT v ALT (p< 0.01). Patients with previous failed ALT had a better reduction in IOP with SLT than with repeat ALT (6.8 (2. 4) v 3.6 (1.8) mm Hg; p = 0.01).

Conclusion: SLT appears to be equivalent to ALT in lowering IOP during the first 6 months after treatment. There is a slightly greater anterior chamber reaction 1 hour after SLT. Patients with previous failed ALT had a significantly greater drop in IOP when treated with SLT v ALT. These results need to be confirmed with a larger sample size.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Trial profile.

Similar articles

Cited by

References

    1. Ophthalmology. 1988 Feb;95(2):277-81 - PubMed
    1. Arch Ophthalmol. 1985 Jun;103(6):793-5 - PubMed
    1. Ophthalmology. 1987 Feb;94(2):171-9 - PubMed
    1. Klin Monbl Augenheilkd. 1992 May;200(5):404-6 - PubMed
    1. Invest Ophthalmol Vis Sci. 1990 Jan;31(1):115-24 - PubMed

Publication types