Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 May;12(2 Suppl 1):148-51.
doi: 10.1007/BF03168785.

Impact of electronic imaging on clinician behavior in the urgent care setting

Affiliations

Impact of electronic imaging on clinician behavior in the urgent care setting

C W Mattern et al. J Digit Imaging. 1999 May.

Abstract

Although it is intuitively valuable that more expedient delivery of radiographic images and reports to clinicians would improve patient care, it is important to document these outcomes to validate further advances in these areas. We evaluated the care of 215 patients seen at a walk-in clinic to determine what benefit digital imaging is to the patient. Cohorts consisted of all patients for whom specified radiology examinations were ordered during a 7-day period. The first cohort was recruited when analog films were used. The second cohort received examinations performed with computed radiography (CR) acquisition and computer display, which had been in use for 2 years. Patients were categorized as to the type of study they received, as well as whether a staff radiologist was immediately available to read the study. Clinical behavior was characterized by outcome measures of time to final diagnosis, time to final treatment, and need for follow-up. Our analysis demonstrated a reduction in time to final diagnosis that was better appreciated during the times when a staff radiologist was not immediately available. It also suggested that greater time reductions were seen for patients who received extremity examinations than those who received chest, sinus, or rib films. These data suggest that digital imaging is a useful tool to improve clinical outcome of patients seen in the acute care setting.

PubMed Disclaimer

References

    1. Mattern CWT, King BF, Hangiandreou NJ, et al. Electronic imaging impact on image and report turnaround times. J Digit Imaging. 1999;12(suppl 1):155–159. doi: 10.1007/BF03168787. - DOI - PMC - PubMed
    1. Bryan S, Weatherburn G, Watkins J, et al. Radiology report times: Impact of picture archiving and communication systems. Am J Roentgenol. 1998;170:1153–1159. - PubMed
    1. Kundel HL, Seshadri SB, Langlotz CP, et al. Prospective study of a PACS: Information flow and clinical action in a medical intensive care unit. Radiology. 1996;199:143–149. - PubMed
    1. Redfern RO, Kundel HL, Seshadri SB, et al. PACS workstation usage and patient outcome surrogates. SPIE. 1997;3035:424–430. doi: 10.1117/12.274599. - DOI
    1. Reiner BI, Siegel EL, Hooper F, et al. Impact of filmless imaging on the frequency of clinician review of radiology images. J Digit Imaging. 1998;11:149–150. doi: 10.1007/BF03168288. - DOI - PMC - PubMed

MeSH terms