Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 May;12(2 Suppl 1):155-9.
doi: 10.1007/BF03168787.

Electronic imaging impact on image and report turnaround times

Affiliations
Comparative Study

Electronic imaging impact on image and report turnaround times

C W Mattern et al. J Digit Imaging. 1999 May.

Abstract

We prospectively compared image and report delivery times in our Urgent Care Center (UCC) during a film-based practice (1995) and after complete implementation of an electronic imaging practice in 1997. Before switching to a totally electronic and filmless practice, multiple time periods were consistently measured during a 1-week period in May 1995 and then again in a similar week in May 1997 after implementation of electronic imaging. All practice patterns were the same except for a film-based practice in 1995 versus a filmless practice in 1997. The following times were measured: (1) waiting room time, (2) technologist's time of examination, (3) time to quality control, (4) radiology interpretation times, (5) radiology image and report delivery time, (6) total radiology turn-around time, (7) time to room the patient back in the UCC, and (8) time until the ordering physician views the film. Waiting room time was longer in 1997 (average time, 26:47) versus 1995 (average time, 15:54). The technologist's examination completion time was approximately the same (1995 average time, 06:12; 1997 average time, 05:41). There was also a slight increase in the time of the technologist's electronic verification or quality control in 1997 (average time, 7:17) versus the film-based practice in 1995 (average time, 2:35). However, radiology interpretation times dramatically improved (average time, 49:38 in 1995 versus average time 13:50 in 1997). There was also a decrease in image delivery times to the clinicians in 1997 (median, 53 minutes) versus the film based practice of 1995 (1 hour and 40 minutes). Reports were available with the images immediately upon completion by the radiologist in 1997, compared with a median time of 27 minutes in 1995. Importantly, patients were roomed back into the UCC examination rooms faster after the radiologic procedure in 1997 (average time, 13:36) than they were in 1995 (29:38). Finally, the ordering physicians viewed the diagnostic images and reports in dramatically less time in 1997 (median, 26 minutes) versus 1995 (median, 1 hour and 5 minutes). In conclusion, a filmless electronic imaging practice within our UCC greatly improved radiology image and report delivery times, as well as improved clinical efficiency.

PubMed Disclaimer

References

    1. Bryan S, Weatherburn G, Watkins J, et al. Radiology report times: Impact of picture archiving and communication systems. Am J Roentgenol. 1998;170:1153–1159. - PubMed
    1. Kundel HL, Seshadri SB, Langlotz CP, et al. Prospective study of a PACS: Information flow and clinical action in a medical intensive care unit. Radiology. 1996;199:143–149. - PubMed
    1. Kundel HL, Seshadri SB, Arenson RL. Clinical experience at the University of Pennsylvania. Comput Med Imaging Graph. 1991;15:197–200. doi: 10.1016/0895-6111(91)90010-S. - DOI - PubMed
    1. Simone DN, Kundel HL, Arenson RL, et al. Effect of a digital imaging network on physician behavior in an intensive care unit. Radiology. 1988;169:41–44. - PubMed
    1. Kato H, Kubota G, Kojima K, et al. Preliminary time-flow study: Comparison of interpretation times between PACS work-stations and films. Comput Med Imaging Graph. 1995;19:261–265. doi: 10.1016/0895-6111(95)00010-N. - DOI - PubMed

Publication types