The comet-tail artifact: an ultrasound sign ruling out pneumothorax
- PMID: 10342512
- DOI: 10.1007/s001340050862
The comet-tail artifact: an ultrasound sign ruling out pneumothorax
Abstract
Objective: Ultrasound artifacts arising from the lung-wall interface are either vertical (comet-tail artifacts) or horizontal. The significance of these artifacts for the diagnosis of pneumothorax was assessed.
Design: Prospective clinical study.
Setting: The medical ICU of a university-affiliated teaching hospital.
Patients: We compared 41 complete pneumothoraces with 146 hemithoraces in 73 critically ill patients in which computed tomography showed absence of pneumothorax.
Measurements: The anterior chest wall was investigated in supine patients using a portable device. The test was defined as positive for complete pneumothorax when only horizontal artifacts were visible, and negative when artifacts arising from the pleural line and spreading up to the edge of the screen (referred to as "comet-tail artifacts") were present.
Results: The feasibility was 98%. Ultrasound showed exclusive horizontal artifacts in all 41 analyzable cases of complete pneumothorax. In the pneumothorax-free group, "comet-tail artifacts" were present in 87 cases and exclusive horizontal artifacts in 56. Ultrasound as well as computed tomography showed anterior consolidation or anterior pleural effusion in three cases. Horizontal artifacts had a sensitivity and a negative predictive value of 100% and a specificity of 60% for the diagnosis of pneumothorax. Horizontal artifacts and absent lung sliding, when combined, had a sensitivity and a negative predictive value of 100% and a specificity of 96.5%.
Conclusions: Ultrasound detection of the "comet-tail artifact" at the anterior chest wall allows complete pneumothorax to be discounted.
Similar articles
-
The "lung point": an ultrasound sign specific to pneumothorax.Intensive Care Med. 2000 Oct;26(10):1434-40. doi: 10.1007/s001340000627. Intensive Care Med. 2000. PMID: 11126253
-
A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding.Chest. 1995 Nov;108(5):1345-8. doi: 10.1378/chest.108.5.1345. Chest. 1995. PMID: 7587439
-
Ultrasound diagnosis of occult pneumothorax.Crit Care Med. 2005 Jun;33(6):1231-8. doi: 10.1097/01.ccm.0000164542.86954.b4. Crit Care Med. 2005. PMID: 15942336
-
Emergency bedside ultrasound to detect pneumothorax.Acad Emerg Med. 2003 Jan;10(1):91-4. doi: 10.1111/j.1553-2712.2003.tb01984.x. Acad Emerg Med. 2003. PMID: 12511323 Review.
-
Lung ultrasound in the critically ill.Curr Opin Crit Care. 2014 Jun;20(3):315-22. doi: 10.1097/MCC.0000000000000096. Curr Opin Crit Care. 2014. PMID: 24758984 Review.
Cited by
-
Intraoperative lung ultrasound: A clinicodynamic perspective.J Anaesthesiol Clin Pharmacol. 2016 Jul-Sep;32(3):288-97. doi: 10.4103/0970-9185.188824. J Anaesthesiol Clin Pharmacol. 2016. PMID: 27625474 Free PMC article. Review.
-
Clinical review: Bedside lung ultrasound in critical care practice.Crit Care. 2007;11(1):205. doi: 10.1186/cc5668. Crit Care. 2007. PMID: 17316468 Free PMC article. Review.
-
Utilization of ultrasound for the detection of pneumothorax in the neonatal special-care nursery.Pediatr Radiol. 2003 Dec;33(12):880-3. doi: 10.1007/s00247-003-0964-z. Epub 2003 Sep 16. Pediatr Radiol. 2003. PMID: 13680003
-
Quantitative lung ultrasonography: a putative new algorithm for automatic detection and quantification of B-lines.Crit Care. 2019 Aug 28;23(1):288. doi: 10.1186/s13054-019-2569-4. Crit Care. 2019. PMID: 31455421 Free PMC article.
-
High-Resolution Computed Tomography and Lung Ultrasound in Patients with Systemic Sclerosis: Which One to Choose?Diagnostics (Basel). 2021 Dec 7;11(12):2293. doi: 10.3390/diagnostics11122293. Diagnostics (Basel). 2021. PMID: 34943531 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical