Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jun;117(6):1144-50.
doi: 10.1016/s0022-5223(99)70251-5.

Mechanical analysis of midline sternotomy wound closure

Affiliations

Mechanical analysis of midline sternotomy wound closure

W E McGregor et al. J Thorac Cardiovasc Surg. 1999 Jun.

Abstract

Objective: Unstable median sternotomy closure can lead to postoperative morbidity. This study tests the hypothesis that separation of the sternotomy site occurs when physiologic forces act on the closure.

Methods: Median sternotomy was performed in 4 human cadavers (2 male) and closed with 7 interrupted stainless steel wires. The chest wall was instrumented to apply 4 types of distracting force: (1) lateral, (2) anterior-posterior, (3) rostral-caudal, and (4) a simulated Valsalva force. Forces were applied in each direction and were limited to physiologic levels (< 400 N). Four sets of sonomicrometry crystals were placed equidistantly along the sternum to measure separation at the closure site.

Results: Sternal separation occurred as a result of the wires cutting through the bone. Less force was needed to achieve 2.0-mm distraction in the lateral direction (220 +/- 40 N) than in the anterior-posterior (263 +/- 74 N) and rostral-caudal (325 +/- 30 N) directions. More separation occurred at the lower end of the sternum than the upper. During lateral distraction, xiphoid and manubrial displacement averaged 1.85 +/- 0.14 and 0.35 +/- 0.12 mm, respectively. Anterior-posterior distraction caused 1.99 +/- 0.04-mm xiphoid displacement and 0.26 +/- 0.12-mm manubrial displacement. During a simulated Valsalva force, more separation occurred in the lateral (2.14 +/- 0.11 mm) than in the anterior-posterior (0.46 +/- 0.29 mm) or rostral-caudal (0.25 +/- 0.15 mm) directions.

Conclusions: These data suggest that sternal dehiscence can occur under physiologic loads and that improved sternal stability may be readily achieved via mechanical reinforcement near the xiphoid. Closure techniques designed to minimize wire migration into the sternum should also be developed.

PubMed Disclaimer

Comment in

Publication types

Substances