On the apparent collapse of stereopsis in random-dot-stereograms at isoluminance
- PMID: 10343795
- DOI: 10.1016/s0042-6989(98)00257-0
On the apparent collapse of stereopsis in random-dot-stereograms at isoluminance
Abstract
We have investigated the apparent collapse of stereopsis obtained with random-dot-stereograms at isoluminance. Contrast thresholds for both depth and form discrimination of targets in random-dot- and figural stereograms were measured at a number of disparitics, using both isoluminant and isochromatic stimuli. All contrast thresholds for stereoscopic tasks were normalised to contrast thresholds for detecting the appropriate stimulus. We found that at isoluminance contrast thresholds for depth judgements were not higher for random-dot compared to figural stereograms, even when normalised to the same thresholds obtained with isochromatic stimuli. On the other hand contrast thresholds for three-dimensional form judgements were much higher than those for depth judgements in isoluminant, compared to isochromatic random-dot-stereograms. This specific impairment of stereoscopic form (as opposed to depth) processing at isoluminance was confirmed in a further experiment in which subjects were required to judge the presence and orientation of depth corrugations in a disparity-modulated random-dot-stereogram.
Similar articles
-
Differences between stereopsis with isoluminant and isochromatic stimuli.J Opt Soc Am A Opt Image Sci Vis. 1995 Oct;12(10):2094-104. doi: 10.1364/josaa.12.002094. J Opt Soc Am A Opt Image Sci Vis. 1995. PMID: 7500200
-
Contrast thresholds for stereoscopic depth identification with isoluminant and isochromatic stimuli.Vision Res. 1994 Nov;34(22):2971-82. doi: 10.1016/0042-6989(94)90269-0. Vision Res. 1994. PMID: 7975331
-
Stereopsis at isoluminance in the absence of chromatic aberrations.J Opt Soc Am A. 1992 Jun;9(6):868-76. doi: 10.1364/josaa.9.000868. J Opt Soc Am A. 1992. PMID: 1607989
-
Toward a neural understanding of visual surface representation.Cold Spring Harb Symp Quant Biol. 1990;55:911-24. doi: 10.1101/sqb.1990.055.01.085. Cold Spring Harb Symp Quant Biol. 1990. PMID: 2132868 Review. No abstract available.
-
Field processes in stereovision. A description of stereopsis appropriate to ophthalmology and visual perception.Doc Ophthalmol. 1987 Jun;66(2):95-170. doi: 10.1007/BF00140453. Doc Ophthalmol. 1987. PMID: 3319467 Review.
Cited by
-
Colour helps to solve the binocular matching problem.J Physiol. 2005 Sep 1;567(Pt 2):665-71. doi: 10.1113/jphysiol.2005.089516. Epub 2005 Jun 23. J Physiol. 2005. PMID: 15975983 Free PMC article. Clinical Trial.
-
A novel clinical dynamic stereopsis assessment based on autostereoscopic display system.Ann Transl Med. 2022 Jun;10(12):656. doi: 10.21037/atm-21-6700. Ann Transl Med. 2022. PMID: 35845544 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources