Effect of dialysate temperature on energy balance during hemodialysis: quantification of extracorporeal energy transfer
- PMID: 10352200
- DOI: 10.1016/S0272-6386(99)70149-6
Effect of dialysate temperature on energy balance during hemodialysis: quantification of extracorporeal energy transfer
Abstract
An impaired vascular response is implicated in the pathogenesis of dialysis-induced hypotension, which is at least partly related to changes in extracorporeal blood temperature (Temp). However, little is known about changes in core Temp and differences in energy balance between standard and cool dialysis. In this study, core Temp and energy transfer between extracorporeal circuit and patient, as well as the blood pressure response, were assessed during dialysis with standard (37.5 degrees C) and cool (35.5 degrees C) Temp of the dialysate. Nine patients (4 men, 5 women; mean age, 69 +/-10 [SD] years) were studied during low- and standard-Temp dialysis, each serving as his or her own control. Bicarbonate dialysis and hemophane membranes were used. Energy transfer was assessed by continuous measurement of Temp in the arterial (Tart) and venous side (Tven) of the extracorporeal system according to the formula: c. rho.Qb*(Tven - Tart)*t, where c = specific thermal capacity (3.64 kJ/kg* degrees C), Qb = extracorporeal blood flow, rho = density of blood (1,052 kg/m3), and t = dialysis time (hours). Core Temp was also measured by Blood Temperature Monitoring (BTM; Fresenius, Bad Homburg, Germany). Core Temp increased during standard-Temp dialysis (36.7 degrees C +/- 0.3 degrees C to 37.2 degrees C +/- 0.2 degrees C; P < 0.05) despite a small negative energy balance (-85 +/- 43 kJ) from the patient to the extracorporeal circuit. During cool dialysis, energy loss was much more pronounced (-286 +/- 73 kJ; P < 0.05). However, mean core Temp remained stable (36.4 degrees C +/- 0.6 degrees C to 36.4 degrees C +/- 0.3 degrees C; P = not significant), and even increased in some patients with a low predialytic core Temp. Both during standard and cool dialysis, the increase in core Temp during dialysis was significantly related to predialytic core Temp (r = 0.88 and r = 0.77; P < 0.05). Systolic blood pressure (RR) decreased to a greater degree during standard-Temp dialysis compared with cool dialysis (43 +/- 21 v 22 +/- 26 mm Hg; P < 0.05), whereas diastolic RR tended to decrease more (15 +/- 10 v 0 +/- 19 mm Hg; P = 0.07). Core Temp increased in all patients during standard-Temp dialysis despite a small net energy transfer from the patient to the extracorporeal system. Concluding, Core Temp remained generally stable during cool dialysis despite significant energy loss from the patient to the extracorporeal circuit, and even increased in some patients with a low predialytic core Temp. The change in core Temp during standard and cool dialysis was significantly related to the predialytic blood Temp of the patient, both during cool- and standard-Temp dialysis. The results suggest that the hemodialysis procedure itself affects core Temp regulation, which may have important consequences for the vascular response during hypovolemia. The removal of heat by the extracorporeal circuit and/or the activation of autoregulatory mechanisms attempting to preserve core Temp might be responsible for the beneficial hemodynamic effects of cool dialysis.
Similar articles
-
Isothermic hemodialysis and ultrafiltration.Am J Kidney Dis. 2000 Aug;36(2):353-61. doi: 10.1053/ajkd.2000.8986. Am J Kidney Dis. 2000. PMID: 10922314
-
The effect of dialysate temperature on energy transfer during hemodialysis (HD).Kidney Int. 1999 Jun;55(6):2598-608. doi: 10.1046/j.1523-1755.2002.t01-1-00457.x. Kidney Int. 1999. PMID: 10354309
-
[Thermal energy balance during hemodialysis: the role of the filter membrane].G Ital Nefrol. 2002 Jul-Aug;19(4):425-31. G Ital Nefrol. 2002. PMID: 12369045 Italian.
-
Haemodialysis with on-line monitoring equipment: tools or toys?Nephrol Dial Transplant. 2005 Jan;20(1):22-33. doi: 10.1093/ndt/gfh555. Nephrol Dial Transplant. 2005. PMID: 15632348 Review.
-
[From dialysate temperature to thermal balance].G Ital Nefrol. 2006 Jan-Feb;23(1):29-36. G Ital Nefrol. 2006. PMID: 16521073 Review. Italian.
Cited by
-
Prevalence and risk factors of intra-dialytic hypotension: a 5 year retrospective report from a single Nigerian Centre.Pan Afr Med J. 2017 Sep 21;28:62. doi: 10.11604/pamj.2017.28.62.13743. eCollection 2017. Pan Afr Med J. 2017. PMID: 29230264 Free PMC article.
-
Pro-inflammatory cytokines as potential predictors for intradialytic hypotension.Ren Fail. 2021 Dec;43(1):198-205. doi: 10.1080/0886022X.2021.1871921. Ren Fail. 2021. PMID: 33459124 Free PMC article.
-
Dialysate temperature reduction for intradialytic hypotension for people with chronic kidney disease requiring haemodialysis.Cochrane Database Syst Rev. 2019 Jul 5;7(7):CD012598. doi: 10.1002/14651858.CD012598.pub2. Cochrane Database Syst Rev. 2019. PMID: 31273758 Free PMC article.
-
Major Outcomes With Personalized Dialysate TEMPerature (MyTEMP): Rationale and Design of a Pragmatic, Registry-Based, Cluster Randomized Controlled Trial.Can J Kidney Health Dis. 2020 Feb 5;7:2054358119887988. doi: 10.1177/2054358119887988. eCollection 2020. Can J Kidney Health Dis. 2020. PMID: 32076569 Free PMC article.
-
Effect of Lowering the Dialysate Temperature in Chronic Hemodialysis: A Systematic Review and Meta-Analysis.Clin J Am Soc Nephrol. 2016 Mar 7;11(3):442-57. doi: 10.2215/CJN.04580415. Epub 2015 Dec 28. Clin J Am Soc Nephrol. 2016. PMID: 26712807 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials