Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Jun;211(3):667-79.
doi: 10.1148/radiology.211.3.r99jn26667.

Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold

Affiliations
Comparative Study

Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold

S O Schoenberg et al. Radiology. 1999 Jun.

Abstract

Purpose: To compare two different three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiographic techniques.

Materials and methods: In 26 patients suspected of having renal artery stenosis, results with fast multiphase 3D MR angiography were compared to those with standard 3D MR angiography in 37 patients. With both techniques, 31-second breath-hold acquisitions were performed. Multiphase angiography comprised five discrete 6.4-second acquisitions without bolus timing, and standard angiography comprised a single acquisition based on test-bolus timing. Two readers evaluated images obtained with both techniques in terms of image quality, artifacts, and vessel conspicuity. Accuracy of findings on the multiphase 3D MR angiograms for assessment of renal artery stenosis was determined by comparing them to digital subtraction angiograms and surgical findings.

Results: In the early arterial phase, multiphase 3D MR angiograms showed no image degradation by venous overlay, whereas standard 3D MR angiograms depicted at least minor overlay in 53 of 83 renal arteries (P < .001). Less parenchymal enhancement in the early arterial phase resulted in a higher vessel conspicuity for the divisions and segmental arteries (P < .001). Both readers detected and correctly graded 18 of 20 stenoses on the multiphase angiograms with almost perfect interobserver agreement (kappa > 0.89).

Conclusion: Renal multiphase 3D MR angiography is an accurate technique requiring no bolus timing. The performance of early arterial phase imaging leads to improved depiction, particularly of the distal renovascular tree, compared to that with standard single-phase 3D MR angiography.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources