How three methods for fixing a medial meniscal autograft affect tibial contact mechanics
- PMID: 10352767
- DOI: 10.1177/03635465990270030901
How three methods for fixing a medial meniscal autograft affect tibial contact mechanics
Abstract
We evaluated three methods for fixing a medial meniscal autograft to determine which method restored tibial contact mechanics closest to normal. The contact mechanics (maximum pressure, mean pressure, contact area, and location of the center of maximum pressure) of the medial tibial articular surface were determined using pressure-sensitive film while knee specimens were loaded in compression to 1000 N at 0 degree, 15 degrees, 30 degrees, and 45 degrees of flexion. Pressure was measured for the intact knee, the knee after meniscectomy, and the knee with the original meniscus removed and reimplanted as an autograft using three different fixation methods. The contact mechanics of the autograft reinserted with bone plug fixation were closest to normal; however, the maximum pressure was significantly greater than in the intact knee. Adding peripheral sutures neither improved nor worsened the contact mechanics. Fixation with sutures only did not restore normal contact mechanics. We concluded that medial meniscal transplantation requires anatomic fixation of bone plugs attached to the anterior and posterior horns to restore contact mechanics closest to normal. Fixation of the meniscal horns with sutures alone cannot be recommended.
Similar articles
-
Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft. A human cadaveric study.Am J Sports Med. 2000 May-Jun;28(3):370-6. doi: 10.1177/03635465000280031501. Am J Sports Med. 2000. PMID: 10843130
-
The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees.J Orthop Res. 2003 May;21(3):459-64. doi: 10.1016/S0736-0266(02)00201-2. J Orthop Res. 2003. PMID: 12706018
-
Bone Plug Versus Suture-Only Fixation of Meniscal Grafts: Effect on Joint Contact Mechanics During Simulated Gait.Am J Sports Med. 2014 Jul;42(7):1682-9. doi: 10.1177/0363546514530867. Epub 2014 Apr 28. Am J Sports Med. 2014. PMID: 24778265 Free PMC article.
-
Allogenic meniscus transplantation.Oper Orthop Traumatol. 2006 Dec;18(5-6):463-80. doi: 10.1007/s00064-006-1189-8. Oper Orthop Traumatol. 2006. PMID: 17171331 Review. English, German.
-
[Stage-based treatment by partial meniscectomy, meniscal refixation and transplantation].Zentralbl Chir. 2005 Aug;130(4):314-20. doi: 10.1055/s-2005-836815. Zentralbl Chir. 2005. PMID: 16103955 Review. German.
Cited by
-
A review of strategies for development of tissue engineered meniscal implants.Biomater Biosyst. 2021 Aug 26;4:100026. doi: 10.1016/j.bbiosy.2021.100026. eCollection 2021 Dec. Biomater Biosyst. 2021. PMID: 36824574 Free PMC article. Review.
-
The influence of pre-tensioning of meniscal transplants on the tibiofemoral contact area.Knee Surg Sports Traumatol Arthrosc. 2006 May;14(5):425-36. doi: 10.1007/s00167-005-0704-z. Epub 2005 Nov 22. Knee Surg Sports Traumatol Arthrosc. 2006. PMID: 16328461
-
Biomechanical considerations are crucial for the success of tendon and meniscus allograft integration-a systematic review.Knee Surg Sports Traumatol Arthrosc. 2019 Jun;27(6):1708-1716. doi: 10.1007/s00167-018-5185-y. Epub 2018 Oct 5. Knee Surg Sports Traumatol Arthrosc. 2019. PMID: 30291394
-
Meniscal allograft transplantation: a review of the current literature.Ann R Coll Surg Engl. 2009 Jul;91(5):361-5. doi: 10.1308/003588409X428559. Epub 2009 Apr 30. Ann R Coll Surg Engl. 2009. PMID: 19409145 Free PMC article. Review.
-
Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.Sci Rep. 2017 Jul 20;7(1):6011. doi: 10.1038/s41598-017-06271-3. Sci Rep. 2017. PMID: 28729605 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources