Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography
- PMID: 10353940
- DOI: 10.1542/peds.103.6.1263
Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography
Abstract
Objective: To define normal and abnormal patterns, test interobserver variability, and the prognostic accuracy of amplitude-integrated electroencephalography (aEEG) soon after the onset of neonatal encephalopathy.
Methods: Consecutive cases of neonatal encephalopathy (n = 56; gestation median, 40; range, 35-42 weeks) and healthy infants (n = 14; gestation median, 40; range, 39-40 weeks) were studied. aEEG was recorded using a cerebral function monitor, at median, 0, range, 0-21 days of age. Of the infants, 24 of the 56 with encephalopathy and all of the normal infants were studied within 12 hours of birth (median, 5; range, 3-12 hours). Forty infants were suspected of having suffered birth asphyxia. Criteria for normal and abnormal patterns were defined and the interobserver variability of these classifications determined. Results were compared with neurodevelopmental outcome assessed at 18 to 24 months of age. aEEG also was compared with a standard EEG and with magnetic resonance imaging.
Results: The median upper margin of the widest band of aEEG activity in the control infants was 37.5 microV (range, 30-48 microV), and median lower margin was 8 microV (range, 6.5-11 microV). We classified the aEEG background activity as normal amplitude, the upper margin of band of aEEG activity >10 microV and the lower margin >5 microV; moderately abnormal amplitude, the upper margin of band of aEEG activity >10 microV and the lower margin </=5 microV; and suppressed amplitude, the upper margin of the band of aEEG activity <10 microV and lower margin <5 microV. Recordings were analyzed further for the presence of seizures, defined as periods of sudden increase in voltage accompanied by a narrowing of the band of aEEG activity. Tests of interobserver variability showed excellent agreement both for assessment of amplitude (kappa statistic = 0.85) and for identification of seizures (kappa statistic = 0.76) There was a close relationship between the aEEG and subsequent outcome: 19 of 21 infants with a normal aEEG finding were normal on follow-up at 18 to 24 months of age, whereas 27 of 35 infants with a moderately abnormal or suppressed aEEG and/or seizures died or developed neurologic abnormalities. Thus, aEEG predicted outcome with a sensitivity of 0. 93, a specificity of 0.70, positive predictive value of 0.77, negative predictive value of 0.90, and the likelihood ratio of a positive result of 3.1 and a negative result of 0.06. For the 24 infants studied within 12 hours of birth, the corresponding results were sensitivity, 1.0; specificity, 0.82; positive predictive value, 0.85; negative predictive value, 1; likelihood ratio of a positive result, 5.5; and likelihood ratio of a negative result, 0.18.
Conclusion: The aEEG is a simple but accurate and reproducible clinical tool that could be useful in the assessment of infants with encephalopathy.
Similar articles
-
[Amplitude-integrated electroencephalographic monitoring in early diagnosis and neurological outcome prediction of term infants with hypoxic-ischemic encephalopathy].Zhonghua Er Ke Za Zhi. 2007 Jan;45(1):20-3. Zhonghua Er Ke Za Zhi. 2007. PMID: 17349143 Chinese.
-
[Amplitude-integrated electroencephalographic changes in neonates with acute bilirubin encephalopathy].Zhonghua Er Ke Za Zhi. 2013 Mar;51(3):221-6. Zhonghua Er Ke Za Zhi. 2013. PMID: 23751586 Chinese.
-
Outcome prediction by amplitude-integrated EEG in adults with hypoxic ischemic encephalopathy.Clin Neurol Neurosurg. 2012 Jul;114(6):585-9. doi: 10.1016/j.clineuro.2011.12.011. Epub 2011 Dec 27. Clin Neurol Neurosurg. 2012. PMID: 22206857
-
Predictive value of amplitude-integrated EEG (aEEG) after rescue hypothermic neuroprotection for hypoxic ischemic encephalopathy: a meta-analysis.J Perinatol. 2017 Jun;37(6):684-689. doi: 10.1038/jp.2017.14. Epub 2017 Mar 2. J Perinatol. 2017. PMID: 28252661 Review.
-
Amplitude-integrated electroencephalography for seizure detection in newborn infants.Semin Fetal Neonatal Med. 2018 Jun;23(3):175-182. doi: 10.1016/j.siny.2018.02.003. Epub 2018 Feb 13. Semin Fetal Neonatal Med. 2018. PMID: 29472139 Review.
Cited by
-
Cerebral function monitoring on a general paediatric ward: feasibility and potential.Eur J Pediatr. 2016 Aug;175(8):1059-64. doi: 10.1007/s00431-016-2737-3. Epub 2016 Jun 6. Eur J Pediatr. 2016. PMID: 27271341
-
EEG monitoring during therapeutic hypothermia in neonates, children, and adults.Am J Electroneurodiagnostic Technol. 2011 Sep;51(3):141-64. Am J Electroneurodiagnostic Technol. 2011. PMID: 21988034 Free PMC article. Review.
-
Efficiency Evaluation of Neuroprotection for Therapeutic Hypothermia to Neonatal Hypoxic-Ischemic Encephalopathy.Front Neurosci. 2021 Sep 28;15:668909. doi: 10.3389/fnins.2021.668909. eCollection 2021. Front Neurosci. 2021. PMID: 34650397 Free PMC article.
-
Next-Generation Wearable Biosensors Developed with Flexible Bio-Chips.Micromachines (Basel). 2021 Jan 7;12(1):64. doi: 10.3390/mi12010064. Micromachines (Basel). 2021. PMID: 33430524 Free PMC article. Review.
-
Prognostic value of serum high-mobility group box 1 in neonates with neonatal encephalopathy.Pediatr Res. 2025 Feb;97(3):1079-1084. doi: 10.1038/s41390-024-03408-9. Epub 2024 Jul 15. Pediatr Res. 2025. PMID: 39009766
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical