Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 May-Jun;15(3):299-308.
doi: 10.3928/1081-597X-19990501-04.

Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia

Affiliations
Comparative Study

Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia

R Zaldivar et al. J Refract Surg. 1999 May-Jun.

Abstract

Purpose: To examine the efficacy, predictability, stability, and safety of combined posterior chamber phakic intraocular lens (IOL) implantation and laser in situ keratomileusis (LASIK) in eyes with extreme myopia.

Methods: We analyzed the results of 67 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (STAAR Collamer Implantable Contact Lens) and also underwent secondary LASIK for the correction of extreme myopia. Mean follow-up was 3 months after the LASIK portion of the procedure (range, 1 day to 6 mo after LASIK).

Results: Mean preoperative spherical equivalent refraction was -23.00 +/- 3.60 D (range, -18.75 to -35.00 D), and mean refractive cylinder was 1.50 +/- 1.20 D (range, 0 to 5.00 D). Mean spherical equivalent refraction after IOL implantation and before LASIK was -6.00 +/- 2.80 D (range, -2.00 to -14.38 D) and mean refractive cylinder 1.50 +/- 1.10 D (range, 0 to 5.00 D). Mean postoperative spherical equivalent refraction at last examination after the LASIK portion of the two-part phakic IOL-LASIK procedure was -0.20 +/- 0.90 D (range, +1.75 to -5.13 D), and mean refractive cylinder was 0.50 +/- 0.50 (range, 0 to 2.25 D). Eighty-five percent (57 eyes) were within +/- 1.00 D and 67% (45 eyes) were within +/- 0.50 D of emmetropia at last examination. The refractions remained stable with a statistically insignificant change (P > .05 at each interval) during follow-up. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 3% (2 eyes) and 20/40 or better in 69% (46 eyes). A gain of 2 or more lines of spectacle-corrected visual acuity was seen in 51 eyes (76%) and no eyes lost 2 or more lines of spectacle-corrected visual acuity at last examination.

Conclusion: Combined posterior chamber phakic IOL implantation with the STAAR Collamer plate lens and LASIK (bioptics) is an effective and reasonably predictable method for correcting myopia from -18 to -35 D. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-term safety and refractive stability.

PubMed Disclaimer

Publication types

LinkOut - more resources