. 1999 Jun;57(6):700-6; discussion 706-8.
doi: 10.1016/s0278-2391(99)90437-8.

Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement

Affiliations

Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement

C E Misch et al. J Oral Maxillofac Surg. 1999 Jun.

Abstract

Purpose: This study sought to establish the relationships between bone density, elastic modulus, and ultimate compressive strength of trabecular bone in the human mandible, and to determine the influence that the cortical plates have on these values.

Materials and methods: Nine fresh-frozen human mandibles between the ages of 56 and 90 years were cut into anterior (incisors and canine), middle (premolars), and distal (molars) sections. Seventy-six cylindrical trabecular bone specimens with bone marrow in situ were then prepared and tested in compression in the vertical direction. These tests were performed at a constant strain rate of 0.01 s(-1) with and without the presence of the cortical plates.

Result: The density of mandibular trabecular specimens with bone marrow in situ ranged from 0.85 to 1.53 g/cm3, with a mean value of 1.14 g/cm3 (SD = 0.15). With the cortical plates present, the elastic modulus ranged from 24.9 to 240.0 megapascals (MPa), with a mean value of 96.2 MPa (standard deviation (SD) = 40.6). Without the cortical plates present, the elastic modulus ranged from 3.5 to 125.6 MPa, with a mean value of 56.0 MPa (SD = 29.6). The ultimate compressive strength of the trabecular bone ranged from 0.22 to 10.44 MPa, with a mean value of 3.9 MPa (SD = 2.7).

Conclusion: This study indicates that the trabecular bone in the human mandible possesses significantly higher density, elastic modulus, and ultimate compressive strength in the anterior region than in either the middle or distal regions. The absence of cortical plates decreases the bone elastic modulus. These findings quantitatively confirm the need for clinical awareness in altering implant treatment plans and/or design in relation to bone density and the presence of the cortical plates.

PubMed Disclaimer

Comment in

  • Is trabecular bone in the mandible different?
    Misch CE, Qu Z, Bidez MW. Misch CE, et al. J Oral Maxillofac Surg. 2000 Feb;58(2):247-8. doi: 10.1016/s0278-2391(00)90361-6. J Oral Maxillofac Surg. 2000. PMID: 10670609 No abstract available.