Automatic segmentation of dynamic neuroreceptor single-photon emission tomography images using fuzzy clustering
- PMID: 10369943
- DOI: 10.1007/s002590050425
Automatic segmentation of dynamic neuroreceptor single-photon emission tomography images using fuzzy clustering
Abstract
The segmentation of medical images is one of the most important steps in the analysis and quantification of imaging data. However, partial volume artefacts make accurate tissue boundary definition difficult, particularly for images with lower resolution commonly used in nuclear medicine. In single-photon emission tomography (SPET) neuroreceptor studies, areas of specific binding are usually delineated by manually drawing regions of interest (ROIs), a time-consuming and subjective process. This paper applies the technique of fuzzy c-means clustering (FCM) to automatically segment dynamic neuroreceptor SPET images. Fuzzy clustering was tested using a realistic, computer-generated, dynamic SPET phantom derived from segmenting an MR image of an anthropomorphic brain phantom. Also, the utility of applying FCM to real clinical data was assessed by comparison against conventional ROI analysis of iodine-123 iodobenzamide (IBZM) binding to dopamine D2/D3 receptors in the brains of humans. In addition, a further test of the methodology was assessed by applying FCM segmentation to [123I]IDAM images (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio] benzyl alcohol) of serotonin transporters in non-human primates. In the simulated dynamic SPET phantom, over a wide range of counts and ratios of specific binding to background, FCM correlated very strongly with the true counts (correlation coefficient r2>0.99, P<0.0001). Similarly, FCM gave segmentation of the [123I]IBZM data comparable with manual ROI analysis, with the binding ratios derived from both methods significantly correlated (r2=0.83, P<0.0001). Fuzzy clustering is a powerful tool for the automatic, unsupervised segmentation of dynamic neuroreceptor SPET images. Where other automated techniques fail completely, and manual ROI definition would be highly subjective, FCM is capable of segmenting noisy images in a robust and repeatable manner.
Similar articles
-
Single-photon emission tomography imaging of serotonin transporters in the non-human primate brain with the selective radioligand [(123)I]IDAM.Eur J Nucl Med. 1999 Aug;26(8):854-61. doi: 10.1007/s002590050459. Eur J Nucl Med. 1999. PMID: 10436198
-
Characterization of [(123)I]IDAM as a novel single-photon emission tomography tracer for serotonin transporters.Eur J Nucl Med. 1999 Aug;26(8):844-53. doi: 10.1007/s002590050458. Eur J Nucl Med. 1999. PMID: 10436197
-
A new single-photon emission computed tomography imaging agent for serotonin transporters: [123I]IDAM, 5-iodo-2-((2-((dimethylamino)methyl)phenyl)thio)benzyl alcohol.J Med Chem. 1999 Feb 11;42(3):333-5. doi: 10.1021/jm9806751. J Med Chem. 1999. PMID: 9986702 No abstract available.
-
D2-receptor imaging with [123I]IBZM and single photon emission tomography in psychiatry: a survey of current status.J Neural Transm Gen Sect. 1995;99(1-3):173-85. doi: 10.1007/BF01271477. J Neural Transm Gen Sect. 1995. PMID: 8579803 Review.
-
Neuroreceptor imaging: new developments in PET and SPECT imaging of neuroreceptor binding (including dopamine transporters, vesicle transporters and post synaptic receptor sites).Curr Opin Neurol. 1998 Aug;11(4):327-33. doi: 10.1097/00019052-199808000-00008. Curr Opin Neurol. 1998. PMID: 9725078 Review.
Cited by
-
IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies.Eur J Nucl Med Mol Imaging. 2006 Sep;33(9):1073-83. doi: 10.1007/s00259-006-0067-9. Epub 2006 Apr 14. Eur J Nucl Med Mol Imaging. 2006. PMID: 16614812
-
The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.Eur J Nucl Med Mol Imaging. 2007 Aug;34(8):1240-53. doi: 10.1007/s00259-006-0357-2. Epub 2007 Feb 8. Eur J Nucl Med Mol Imaging. 2007. PMID: 17287959
-
PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.Eur J Nucl Med Mol Imaging. 2010 Nov;37(11):2165-87. doi: 10.1007/s00259-010-1423-3. Epub 2010 Mar 25. Eur J Nucl Med Mol Imaging. 2010. PMID: 20336455 Review.
-
Automatic semi-quantification of [123I]FP-CIT SPECT scans in healthy volunteers using BasGan version 2: results from the ENC-DAT database.Eur J Nucl Med Mol Imaging. 2013 Apr;40(4):565-73. doi: 10.1007/s00259-012-2304-8. Epub 2012 Dec 12. Eur J Nucl Med Mol Imaging. 2013. PMID: 23232506
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources