Evaluation of six erythropoietin kits
- PMID: 10376082
- DOI: 10.1177/000456329903600312
Evaluation of six erythropoietin kits
Abstract
Six erythropoietin (EPO) measurement kits from different manufacturers were evaluated for ease of use and performance. Reference values were compared from patient samples with normal and abnormal circulating serum EPO. The kits evaluated were EPO-Trac RIA, EPORIA, DSL RIA, EPO EIA, IBL ELISA and Medac ELISA (see below for manufacturers' details). The radioimmunoassay (RIA) methods were simple to perform with little preliminary preparation of reagents but the non-isotopic methods were of varying degrees of complexity. Imprecision data showed that performance of the RIA methods was acceptable across the range 40-150 mU/mL [within-assay coefficient of variation (CV) = 2-5%, between-assay CV = 3-7%] but poor (CV > 10%) at the lower end of the range (10-15 mU/mL). The IBL enzyme-linked immunosorbent assay (ELISA) kit showed good precision across the range 10-54 mU/mL (within-assay CV = 5-7%, between-assay CV = 8-12%). The performance of the EPO enzyme immunoassay (EIA) and Medac ELISA were acceptable although precision was poor at the lower end of the range (< 10 mU/mL; within-assay CV 10% and 17% and between-assay CV 13% and 18%, respectively). The ELISA and EIA methods had lower limits of detection (0.4-0.8 mU/mL) than the RIA methods (2.3-3.6 mU/mL). Analysis of serum EPO measurement variation between methods showed evidence of significant negative bias with DSL RIA and Medac ELISA when compared with EPO-Trac RIA. Conversely, EPORIA showed significant positive bias and the two remaining methods, EPO EIA and IBL ELISA, showed no evidence of systematic bias when compared with EPO-Trac RIA. Patients with normal circulating concentration of serum EPO gave values that were within the reference range of the kits.
Similar articles
-
Assessment of an EIA for measuring human serum erythropoietin as compared with RIA and an in-vitro bioassay.Br J Haematol. 1992 Apr;80(4):431-6. doi: 10.1111/j.1365-2141.1992.tb04554.x. Br J Haematol. 1992. PMID: 1581228
-
Application of a modified INCSTAR Epo-trac 125/RIA for measurement of serum erythropoietin concentration in elite athletes.Clin Biochem. 1995 Dec;28(6):573-80. doi: 10.1016/0009-9120(95)00039-7. Clin Biochem. 1995. PMID: 8595704
-
Evaluation of immunoassays for the measurement of erythropoietin (EPO) as an indirect biomarker of recombinant human EPO misuse in sport.J Pharm Biomed Anal. 2004 Sep 3;35(5):1169-77. doi: 10.1016/j.jpba.2004.02.001. J Pharm Biomed Anal. 2004. PMID: 15336362
-
Are current methods of measurement of erythropoietin (EPO) in human plasma or serum adequate for the diagnosis of polycythaemia vera and the assessment of EPO deficiency?Scand J Clin Lab Invest. 1998 Oct;58(6):441-58. doi: 10.1080/00365519850186247. Scand J Clin Lab Invest. 1998. PMID: 9832336 Review.
-
Determination of serum erythropoietin. Its value in the differential diagnosis of polycythemias.Nouv Rev Fr Hematol (1978). 1994 Apr;36(2):173-6. Nouv Rev Fr Hematol (1978). 1994. PMID: 8036136 Review.
Cited by
-
Longitudinal evaluation of laboratory results and method precision in worldwide erythropoietin external quality assessments.Front Mol Biosci. 2024 Jun 21;11:1390079. doi: 10.3389/fmolb.2024.1390079. eCollection 2024. Front Mol Biosci. 2024. PMID: 38974321 Free PMC article.
-
New automated chemiluminescent assay for erythropoietin.J Clin Lab Anal. 2000;14(6):271-3. doi: 10.1002/1098-2825(20001212)14:6<271::aid-jcla4>3.0.co;2-8. J Clin Lab Anal. 2000. PMID: 11138608 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials