RETRACTED: A pilot efficacy study with a single-rod contraceptive implant (Implanon) in 200 Indonesian women treated for < or = 4 years
- PMID: 10382079
- DOI: 10.1016/s0010-7824(99)00015-3
RETRACTED: A pilot efficacy study with a single-rod contraceptive implant (Implanon) in 200 Indonesian women treated for < or = 4 years
Retraction in
-
Implanon studies conducted in Indonesia.Contraception. 2004 Nov;70(5):433. doi: 10.1016/j.contraception.2004.07.004. Contraception. 2004. PMID: 15504385 No abstract available.
-
Retraction notice to "A pilot efficacy study with a single-rod contraceptive implant (Implanon®1) in 200 Indonesian women treated for ≤ 4 years" [Contraception 59/3 (1999) 167-174].Contraception. 2025 Oct;150:110999. doi: 10.1016/j.contraception.2025.110999. Epub 2025 Jul 24. Contraception. 2025. PMID: 40713206 No abstract available.
Abstract
In this 4-year open-label, noncomparative, single-center pilot efficacy study, the contraceptive efficacy, safety, bleeding pattern and acceptability of Implanon was studied in 200 sexually active women of proven fertility in Indonesia. All subjects received the single-rod subdermal implant Implanon, which contains 68 mg etonogestrel (3-keto-desogestrel), with an initial release rate of 67 micrograms etonogestrel/day. Contraceptive efficacy was analyzed by calculation of the pregnancy rate, bleeding patterns were determined by the 90-day reference period method, and acceptability by the discontinuation rate. No in-treatment pregnancies were reported during 658.4 women-years of exposure, resulting in a Pearl Index of 0.0 (95% CI 0.0-0.6). The overall bleeding pattern was acceptable, with no discontinuations because of irregular bleeding. Incidence of irregular bleeding was highest during the first two reference periods and decreased thereafter. Amenorrhea was experienced by 7%-12% of subjects during years 1 and 2, by 5%-7% during year 3, and by 2%-5% during year 4, with one discontinuation because of amenorrhea. No clinically significant changes were reported for systolic and diastolic blood pressure, body mass index, and hemoglobin level. Three adverse experiences were related to treatment and resulted in discontinuation (two headaches and one dyspnea). One difficult implant removal was reported. In conclusion, this pilot efficacy study indicates that Implanon provides excellent contraceptive reliability and an acceptable bleeding pattern. Overall safety and acceptability are good, as suggested by the low incidence of adverse experiences and the low discontinuation rate.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical