Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 May;12(3):221-31.
doi: 10.1016/s1386-6532(98)00011-0.

Evaluation of BC-3 and BCP-1 cell lines in immunofluorescence assay to detect HHV-8 antibodies in Kaposi's sarcoma, multiple myeloma and other groups

Affiliations

Evaluation of BC-3 and BCP-1 cell lines in immunofluorescence assay to detect HHV-8 antibodies in Kaposi's sarcoma, multiple myeloma and other groups

J P Couty et al. J Clin Virol. 1999 May.

Abstract

Background: We describe a comparative study of an immunofluorescence assay using inducible BC-3 and BCP-1 cell lines as sources of HHV-8 antigens.

Study design: Detection of both antibodies to proteins expressed in lytic cycle and during latency in sera from HIV-infected patients with KS, HIV-positive patients without KS, normal blood donors, HIV-negative pregnant women and HIV-negative patients with multiple myeloma. Where possible, detection of antibody was associated with nested PCR detection of HHV-8 in peripheral mononuclear cell (PBMC) samples collected from AIDS-KS patients.

Results: Immunofluorescence was more intense with the BC-3 cell line than with BCP-1, thus facilitating examination under the microscope. HHV-8 antibodies were detected among 82.75% of AIDS-KS patients, in 27.3% of HIV-infected homosexual men, 2% of blood donors and in 2% of pregnant women. No HHV-8 antibodies were detected in serum samples from HIV-negative patients presenting multiple myeloma. HHV-8 DNA sequences were detected and confirmed by southern blot hybridization in five out of 17 (29.4%) PBMC samples from AIDS-KS patients. Titre of antibodies to proteins expressed in lytic cycle was much higher than the titre of antibodies to proteins expressed during latency.

Conclusions: Both immunofluorescence assays were found useful and HHV-8 seroprevalence rates reported in previous studies were confirmed. In addition, results obtained using these assays tend to provide evidence for a lack of epidemiological association between HHV-8 infection and development of multiple myeloma.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources