Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Apr;18(4):256-9.
doi: 10.1007/s100960050273.

Comparison of three different commercial methods for measuring plasma viraemia in patients infected with non-B HIV-1 subtypes

Affiliations
Comparative Study

Comparison of three different commercial methods for measuring plasma viraemia in patients infected with non-B HIV-1 subtypes

A Holguín et al. Eur J Clin Microbiol Infect Dis. 1999 Apr.

Abstract

In order to determine whether commercial assays presently in use for the quantification of plasma human immunodeficiency virus type 1 (HIV-1) RNA levels detect different genetic viral subtypes with the same reliability, a panel of 38 samples corresponding to 22 HIV-1-infected patients, representing non-B subtypes A-F, was examined. One to three plasma samples belonging to each individual were tested by the second-generation HIV-1 branched DNA (bDNA) assay (Chiron, Spain), the Nuclisens assay (Organon-Teknika, Spain), the Amplicor Monitor reverse transcriptase polymerase chain reaction assay (Roche, Spain), and the Ultradirect Monitor (Roche) using primers specifically designed to amplify non-B HIV-1 subtypes. Each of the different methods for measuring viral load showed a distinct sensitivity for non-B HIV-1 subtypes. Values higher than the assay detection limit were obtained in 22 (57.9%), 33 (86.8%), and 37 (93.3%) samples using the bDNA, Nuclisens, and Monitor assays, respectively. Significantly different values (>0.5 logs) were found in 55.3%, 81.6%, and 71.1% of specimens comparing results provided by bDNA and Nuclisens, bDNA and Monitor, and Nuclisens and Monitor, respectively. Quantitative values provided by the Ultradirect Monitor test using non-B primers were particularly discordant with the other tests. Overall, 44.7% of samples yielded higher viral load values with this assay than with the regular Monitor assay, reflecting its enhanced sensitivity for non-B subtypes; however, the reproducibility of this test was low. These results support the recommendation of always using the same assay when monitoring plasma viraemia.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources