Background: To determine the interpretability of gated thallium-201 perfusion SPECT compared with that performed by use of technetium-99m sestamibi (MIBI), 33 patients with prior myocardial infarction were studied. Patients received 22 to 30 mCi (814 to 1110 MBq) MIBI at peak stress, and a 15-minute gated SPECT acquisition was begun 30 to 40 minutes thereafter. On a subsequent day gated Tl-201 SPECT was acquired for 15 minutes, 4 hours after a resting 3.5 mCi (130 MBq) injection. SPECT was performed over a 180-degree arc by use of a 90-degree angled 2-detector camera.
Results: Gated studies were interpreted independently by 4 experienced physicians. Study quality was graded (0 = uninterpretable to 4 = excellent). Wall motion (0 = normal to 2 = akinetic/dyskinetic) and wall thickening (0 = normal to 2 = absent) were graded for each of 10 segments viewed in orthogonal planes. Left ventricular ejection fraction (LVEF) was calculated by use of software thus far validated only for MIBI. The average count density of mid-ventricular end-diastolic short axis tomograms with sestamibi was 3.47 times greater than with thallium. Mean study quality was 3.4 for MIBI and 1.8 for thallium (P < 10(-6)). No gated MIBI SPECTs, but 2 gated thallium studies (6%) were judged uninterpretable. Among interpretable scans, interobserver agreement (Kendall statistic) in assessing wall motion was 0.73 for MIBI and 0.66 for thallium (P = .01). For assessing wall thickening, the Kendall statistic was 0.73 for MIBI and 0.69 for thallium (P = .05). Correlation (r) of LVEFs was 0.91, SEE = 6.4.
Conclusions: We conclude that gated thallium SPECT is inferior to MIBI because of much poorer image quality and somewhat poorer interobserver agreement among experienced physicians. However, LVEF can be determined reliably from gated thallium SPECT.
Similar articles
-
Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT.J Nucl Med. 1997 May;38(5):749-54. J Nucl Med. 1997. PMID: 9170440
-
Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT.J Nucl Med. 1993 Nov;34(11):1871-6. J Nucl Med. 1993. PMID: 8229227
-
201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.J Nucl Med. 1999 May;40(5):805-9. J Nucl Med. 1999. PMID: 10319754
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
Comparison of global and regional left ventricular function assessed by gated-SPECT and 2-D echocardiography.Rev Port Cardiol. 2000 Feb;19 Suppl 1:I39-46. Rev Port Cardiol. 2000. PMID: 10750438 Review.
Cited by
-
Factors affecting accuracy of ventricular volume and ejection fraction measured by gated tl-201 myocardial perfusion single photon emission computed tomography.Int J Cardiovasc Imaging. 2006 Oct;22(5):671-81. doi: 10.1007/s10554-006-9098-3. Epub 2006 May 12. Int J Cardiovasc Imaging. 2006. PMID: 16691365
-
Improved diagnosis and prognosis using Decisions Informed by Combining Entities (DICE): results from the NHLBI-sponsored Women's Ischemia Syndrome Evaluation (WISE).Cardiovasc Diagn Ther. 2013 Dec;3(4):216-27. doi: 10.3978/j.issn.2223-3652.2013.10.07. Cardiovasc Diagn Ther. 2013. PMID: 24400205 Free PMC article.
-
Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function.J Nucl Cardiol. 2001 Mar-Apr;8(2):182-7. doi: 10.1067/mnc.2001.112753. J Nucl Cardiol. 2001. PMID: 11295696
-
Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography.J Nucl Cardiol. 2001 Jan-Feb;8(1):31-9. doi: 10.1067/mnc.2001.109863. J Nucl Cardiol. 2001. PMID: 11182707
-
Thallium-201 gated single-photon emission tomography for assessing left ventricular volumes and function in patients with aortic valve stenosis: Comparison with echocardiography as the reference standard.Int J Cardiol Heart Vasc. 2014 Oct 8;5:74-78. doi: 10.1016/j.ijcha.2014.09.001. eCollection 2014 Dec. Int J Cardiol Heart Vasc. 2014. PMID: 28785618 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical