Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Jul;45(7):995-1001.

Optimization of allopurinol challenge: sample purification, protein intake control, and the use of orotidine response as a discriminative variable improve performance of the test for diagnosing ornithine carbamoyltransferase deficiency

Affiliations
  • PMID: 10388475
Clinical Trial

Optimization of allopurinol challenge: sample purification, protein intake control, and the use of orotidine response as a discriminative variable improve performance of the test for diagnosing ornithine carbamoyltransferase deficiency

J A Arranz et al. Clin Chem. 1999 Jul.

Abstract

Background: The diagnosis of heterozygosity for X-linked ornithine carbamoyltransferase (OCT) deficiency has usually been based on measurement of the increase of orotate and orotidine excretion after an allopurinol load. We examined the choices of analyte, cutoff, and test conditions to obtain maximal test accuracy.

Methods: Urine orotate/orotidine responses to allopurinol load in 37 children (13 OCT-deficient and 24 non-OCT-deficient) and 24 women (7 at risk for carrier status and 17 not related to OCT-deficient children) were analyzed by liquid chromatography after sample purification by anion-exchange chromatography. Diagnostic accuracy was evaluated by nonparametric ROC curves.

Results: Sample purification was necessary to prevent interferences. Orotate and orotidine excretion increased with increased protein intake during the test. At a cutoff of 8 mmol orotidine/mol creatinine, sensitivity was 1.0 and specificity was 0. 92 in mild forms of OCT deficiency. Results in monoplex carrier women may differ greatly from those expected because of the genetics of this deficiency.

Conclusions: Standardization of protein intake is required in the allopurinol loading test. A negative response in the face of clinical suspicion should be followed with a repeat test during a protein intake not <2.5 g x kg-1 x day-1. Measurements of orotidine provide better clinical sensitivity than measurements of orotate.

PubMed Disclaimer

Publication types

LinkOut - more resources